Voltage level: three phase 400V.
Applicable motor capacity: 500kw.
Substrate coating: have.
Built in DC reactor.
The operating frequency of the fixed alternating current is converted to DC power.
Can use the encoder to perform vector control.
Combined use of the position detector (PLG) with the position of the main shaft of the working machine,
Can be carried out on the position of the spindle stop (directional) control.
The speed is kept constant through feedback motor rotation speed. MITSUBISHI inverter series: FR-F820 MITSUBISHI FR-CC2-H500K-60.
Voltage level: three phase 200V.
Power: 18
FR-CC2-H500K-605kw.
SLD converter rated current: 93A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
PID target value can be set directly from the operator panel. Flexible change settings.
In the 1 inverter, through the PID control of parallel connection pump (up to 4 units) can adjust the amount of water and so on MITSUBISHI FR-CC2-H500K-60.
1 pumps driven by parallel connection of the pump machine, in addition to the pump for power frequency drive.
The number of power frequency driven pump, according to the automatic adjustment of water.
The liquid crystal panel options (FR-LU08) can be converted to a more intuitive display unit% units.
Through the use of wind, temperature and other familiar units can be simple to maintain and adjust the display MITSUBISHI FR-CC2-H500K-60. MITSUBISHI inverter FR-D740 series.
Voltage level: three phase 400V.
Frequency converter capacity: 1.5KW.
The internal and back of the inverter structure considering the cooling effect, the relationship between the upper and lower ventilation is also important,
Therefore, in order for the type of unit, hanging on the wall to the vertical position, the installation of vertical as possible FR-CC2-H500K-60 MITSUBISHI FR-CC2-H500K-60 MITSUBISHI.
Transducer can be used to drive a single phase motor? Can single phase power supply be used?
Basically can not be used. For a single phase motor with governor switch, the auxiliary winding will be burnt when the speed is below the operating point;
For the capacitor start or capacitor operation mode, the capacitor explosion will be induced FR-CC2-H500K-60 MITSUBISHI.
The inverter power supply is usually 3, but the capacity for small, single-phase power is also useful functioning aircraft FR-CC2-H500K-60. Power: 30kw.
Purpose: to suppress the power harmonics.
Connected to the inverter input, can be used to improve the power factor, reduce the input side of the high harmonic current.
According to the mmotor power used to select AC reactor MITSUBISHI FR-CC2-H500K-60.
(when the inverter capacity is greater than the motor capacity, is still based on the motor capacity to choose.)