FR-F820-04750-2-60 MITSUBISHI FR-F820-04750-2-60

Brand: MITSUBISHI
Name: Three phase 200V grade frequency converter
Model: FR-F820-04750-2-60
MITSUBISHI inverter series: FR-F820.
Voltage level: three phase 200V.
Power: 90kw.
SLD converter rated current: 475A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
PID target value can be set directly from the operator panel. Flexible change settings.
In the 1 inverter, through the PID control of parallel connection pump (up to 4 units) can adjust the amount of water and so on.
1 pumps driven by parallel connection of the pump machine, in addition to the pump for power frequency drive.
The number of power frequency driven pump, according to the automatic adjustment of water.
The liquid crystal panel options (FR-LU08) can be converted to a more intuitive display unit% units.
Through the use of wind, temperature and other familiar units can be simple to maintain and adjust the display.

Use: dialog type LCD display parameter unit.
Applicable frequency converter: FR-A700, FR-F700, FR-E700, FR-D700. Power: 1.5kw.
Purpose: high frequency braking resistor.
The use rate of the built-in regenerative brake of the transducer can be promoted.
When using the FR-ABR type brake resistor, the short circuit piece between the terminal PR-PX is removed MITSUBISHI FR-F820-04750-2-60. Does not remove the short circuit chip will lead to overheating of the brake resistor FR-F820-04750-2-60
The utilization rate of the regenerative braking should be less than the allowable brake use rate in the above table.
With the operating frequency of the brake resistor to reach 300 degrees C or higher, it is necessary to take protective measures and cooling MITSUBISHI FR-F820-04750-2-60.
MYS type resistor can be used. But please pay attention to the allowable brake use rate.
Do not remove the terminal P/+ and P1 between the short circuit chip, in addition to connecting the DC reactor.
The installation of thermal relay, to avoid overheating and burn the braking resistor. MITSUBISHI inverter FR-E720 series.
Voltage level: 3 phase 200V.
Frequency converter capacity: 0.4KW.
In order to ensure the reliability of production, all production machinery in the design of power with drive, there is a certain amount of surplus MITSUBISHI FR-F820-04750-2-60.
When the motor can not run under full load, in addition to meet the requirements of power driven,
The surplus torque increases the active power consumption, resulting in the waste of electric energy.
Speed control method of fan and pump equipment traditional by regulating the entrance or exit of the baffle, valve opening to regulate air flow and water flow
, the input power is large, and a large amount of energy consumption in the baffle, the valve in the process of closure.
When using variable frequency control, if the flow rate is reduced, the speed of the pump or fan can be reduced to meet the requirements. MITSUBISHI inverter FR-A740 series.
Voltage level: 3 phase 400V.
Frequency converter capacity: 110KW.
Frequency converter is the application of frequency conversion technology and micro electronics technology, by changing the motor operating power frequency mode to control the AC motor power control equipment.
The converter is composed of rectifier (AC), filter, inverter (DC), braking unit, driving unit, micro processing unit of the detecction unit FR-F820-04750-2-60.
Inverter by the internal IGBT to adjust the output power supply voltage and frequency,
According to the actual needs of the motor to provide the required power supply voltage, and then achieve the purpose of energy savving, speed control, in addition to the,
Inverter has a lot of protection functions, such as over current, over voltage, overload protection and so on FR-F820-04750-2-60.