Total input and output points: 16 points.
Input points: 16 points.
Output type: DC24V.
FX2N extension module.
The expansion module is an input and output expansion device of the power supply from the basic unit or the expansion unit,
Can choose the relay or crystal output models, to 8 points for the unit to connect.
When connecting to FX3UC or FX3GC, you need FX2NC-CNV-IF or FX3UC-1PS-5V.
The number of connection points depends on the basic unit and the expansion unit.
Analog input points: 4 channels
Voltage input range: DC0~10V.
Current input range: DC-20~20mA.
High precision analog input module with resolution of 11 bit binary + sign 1 bit, 10 bit binary + symbol 1 bit.
Can be 4 channel voltage input, or current input. Specifications: according to the connection source FX2N-16EX MITSUBISHI.
Corresponding models: FX3GA, FX3G, FX3GE, FX3GC, FX3U, FX3UC. Max input / output points: 48 points
FX2N-16EX
Power supply voltage: 24VDC.
Input points: 24 points.
Output points: 24 points.
Output type: relay.
Power consumption: 30W.
Weight (kg):0.85.
Size (WxHxD) mm:182x90x87.
Note recording function, Component annotation can be recorded in the program register.
Online program editor, online change the program will not lose the working hours or stop production operation FX2N-16EX MITSUBISHI.
RUN/STOP switch, running on panel / stop switch easy to operate.
Remote maintenance, remote programming software can monitor, upload or uninstall programs and data via modem communications
Password protection, using a eight digit password to protect your program.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard FX2N-16EX MITSUBISHI.
Continuous scanning function, to define the operation cycle for the application of the continuous scan time.
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017). Maximum file size: 512MB.
Data form: CSV form.
Weight: 0.3kg.
PLC data can be saved in the form of CF to CSV.
1, can save up to 254, 32767 row of data.
2, save the CSV file can be read through the table count software, and in the form of graphics display, ease of analysis.
PLC can be read through the collected data.
Long time to collect data, through the file FIFO function,
You can automatically generate new files and automatically overwrite the old files, to achhieve the continuous collection of data FX2N-16EX.
Record the historical data before and after the alarm,
In a file to collect data buffer storage file will play a.
FX3U, FX3UC version 2.61 or more can be used, the need to connect the FX3U when the expansion board FX2N-16EX.
The communication function expansion board and the communication special adapter are the same, the communication occupies 1 channels.