Output: 16 points.
Function: bidirectional thyristor output models.
Corresponding models: FX3GA, FX3G, FX3GE, FX3GC, FX3U, FX3UC.
Can carry on the FX3GC, the FX3UC basic unit and the expansion module or the localization module the connector and the terminal station transformation,
Save the time of the input and output connection, realize the labor saving FX2N-8AV-BD MITSUBISHI.
The use of built-in input and output components models,
Can receive AC100V input, or through the relay or the transistor to drive large capacity load
FX2N-8AV-BD Use FX3S-CNV-ADP when connecting to the left of the basic unit of the FX3SA, FX3U, and FX3S.Total input and output points: 16 points.
Input points: 16 points.
Output type: DC24V.
FX2N extension module FX2N-8AV-BD MITSUBISHI.
The expansion module is an input and output expansion device of the power supply from the basic unit or the expansion unit,
Can choose the relay or crystal output models, to 8 points for the unit to connect.
Can be extended to FX3GA/FX3G, FX3GE, FX3GC, as well as FX3U, FX3UC series,
When connecting to FX3UC or FX3GC, you need FX2NC-CNV-IF or FX3UC-1PS-5V.
The number of connection points depends on the basic unit and the expansion unit FX2N-8AV-BD MITSUBISHI. Use FX3S-CNV-ADP when connecting to the left of the basic unit of the FX3GA, FX3U, and FX3G.Max input / output points: 64 points.
Power supply voltage: 24VDC.
Input points: 32 points.
Output points: 32 points.
Output type: relay.
Power consumption: 35W.
Weight (kg):1.0.
Size (WxHxD) mm:220x90x87.
Note recording function, Component annotation can be recorded in the program register.
Online program editor, online change the program will not lose the working hours or stop production operation.
RUN/STOP switch, running on panel / stop switch easy to operate.
Remote maintenance, remote programming software can monitor, upload or uninstall programs and data via modem communications
Password prottection, using a eight digit password to protect your program FX2N-8AV-BD.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard.
Continuous scanning function, to define the operation cycle for the application off the continuous scan time FX2N-8AV-BD.
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017).