LK166
Home >> Products >> OMRON >> Relay >> Solid-state relay >> Solid state relay has the same shape as general relay >> G3F-203SLN-VD DC5 OMRON G3F-203SLN-VD DC5

G3F-203SLN-VD DC5 OMRON G3F-203SLN-VD DC5

Brand: OMRON
Name: Solid State Relays
Model: G3F-203SLN-VD DC5
Isolation: Phototriac coupler.
Zero cross function: No.
Indicator: Yes.
Rated output load: 3 A at 100 to 240 VAC (See note 1.).
Rated input voltage: 5 VDC.
International Standards for G3F Series,
Same Profile as MY Power Relays.
Shape-compatible with mechanical relays.
Certified by UL, CSA, and VDE (model numbers with a suffix of“-VD”).
Socket type, same size as MY Power Relays.
Operation indicator provided to confirm input.
(model numbers with “N” before the suffix).

Insulation method: Photocoupler.
Operation indicator: Yes (yellow).
Zero cross function: Yes.
Applicable output load: 75 A, 100 to 240 VAC.
Rated input voltage: 5 to 24 VDC.
High-power, Load-control SSRs with.
High Current of 75 or 150 A and High.
Voltage of 240 or 480 VAC.
RoHS compliant.
Models also available with no zero cross OMRON G3F-203SLN-VD DC5.
Replaceable power elements.
Conforms to cULus standards and EN standards (TÜV certification) G3F-203SLN-VD DC5 Insulation method: Photocoupler.
Operation indicator: Yes (yellow).
Zero cross function: Yes.
Applicable output load: 150 A, 180 to 480 VAC.
Rated input voltage: 5 to 24 VDC.
High-power, Load-control SSRs with.
High Current of 75 or 150 A and High.
Voltage of 240 or 480 VAC OMRON G3F-203SLN-VD DC5.
RoHS compliant.
Models also available with no zero cross.
Replaceable power elements.
Conforms to cULus standards and EN standards (TÜV certification). Insulation mode: three end two-way switch coupler.
Zero trigger function: No.
Action indicator: there.
Applicable load of output: AC5 240V ~ DC5 1.0A ~ 100V.
Input rated voltage: DC5V.
With the same shape of the power FET MOS G2R relay AC/DC dual, can achieve 1A load switching performance OMRON G3F-203SLN-VD DC5.
Can achieve AC240V or DC100V, 1A load switch.
Output open circuit leakage current: 10 A.
Input / output voltage resistance AC2500V.
Built in input resistance and over voltage absorbing circuit.
Can be carried out AC full wave rectifier load, half wave rectifier load switch.
Number of elements: 3.
Isolation method: Phototriac coupler.
Rated powersupply voltage: 12 to 24 VDC.
Input method: No-voltage input (open and short circuited input).
Applicable monitor capacity (AC3): 0.75 kW (4.8 A), 200 to 220 VAC.
Monitor output: DC switching outputt G3F-203SLN-VD DC5.
New Models with AC Power Supply Input and,
Monitor Output Equivalent to Non-contact,
SPST-NO Join the G3J-T Series,
Limiting the starting current saves energy.
Certified for UL and CSA.
Mounts with screws or to DIN Track.

Compact design with heat sinks (3 G3F-203SLN-VD DC5. 7-kW models: 100 × 100 ×130 mm (W × H × D)).
Built-in snubber circuit and thyristor.
Built-in operation indicator.


...More relevant models >>>>