Isolation: Photo-voltage coupler.
Zero cross function: No.
Indicator: Yes.
Rated output load: 0.5 A at 24 to 240 VAC, 0.5 A at 24 to 110 VDC.
Rated input voltage: 12 VDC.
100-A-max. Leakage Current, No Bleeder.
Resistor Required.
1 mA to 500 mA micro-load switching.
Switch to both AC and DC with no polarity.
Switch for a wide range of voltages; 19.2 to 264 VAC, 19.2 to 125 VDC.
Switch full- and half-wave rectifier AC loads.
Relay MY Series.
Operating indicator provided.
Switch MY Series (without bleeder resistor).
Superior surge absorption with a built-in varistor.
Optimum SSR to control minute load, valves, and solenoids.
Number of phases: Three-phase.
Insulation method: Phototriac coupler.
Operation indicator: Yes (yellow).
Rated input voltage: 12 to 24 VDC.
Zero cross function: Yes.
Type: Externally attached heat sinks.
Applicable load: 25 A, 200 to 480 VAC.
Number of pole: 2.
Compact, Slim-profile SSRs with Heat Sinks OMRON G3FM-2R5SLN DC12.
Solid State Contactors for Three-phase.
Heaters Reduced Installation Work
G3FM-2R5SLN DC12
with DIN Track Mounting.
RoHS compliant.
Surge pass protection improved surge dielectric strength,
for output currents. (OMRON testing).
Slim design with 3-phase output and built-in heat sinks.
DIN Track mounting types and screw mounting types are available.
All DIN Track mounting types mount to DIN Track OMRON G3FM-2R5SLN DC12.
(applicable DIN Track: TR35-15Fe (IEC 60715)).
Conforms to UL, CSA, and EN standards (TÜV certification). Action indicator: built-in type of mechanical indicator.
Number of contacts: 4 pole.
Operating coil voltage: AC200/220V.
Universal relay the best-selling MY standard mechanical indicator, can confirm the action state contact.
According to the LED action indicator light color, can identify the AC coil specifications, DC coil specifications OMRON G3FM-2R5SLN DC12.
Online lap tape printing operation coil specifications, the recognition is higher.
All standard specifications indicating mechanism of mechanical action (mechanical indicator) G3FM-2R5SLN DC12 OMRON.
Suitable for environmental protection RoHS.
Conforms to the UL, CSA, IEC (VDE) standardClassification: Standard models.
Rated voltage: Standard products, 12, 24, 100/110, or 200/220 VAC,
12, 24, 48, or 100/110 VDC; Made-to-order items, 110/120 or 220/240 VAC G3FM-2R5SLN DC12 OMRON.
New Latching Levers for Circuit Checking.
Added to Our Best-selling.
MY General-purpose Relays.
Now lead-free to protect the environment.
VDE certification (Germany) G3FM-2R5SLN DC12 OMRON.
Different colors of coil tape for AC and,
DC models to more easily distinguish them.
MY(S) models with latching levers added for,
easier circuit checking. Type: Models with LED Indicator (See note 2.).
Terminals: Plug-in.
Contact form: 3PDT.
Internal connections (See note 3.): Standard.
With mechanical indicator and lockable test button.
Coil ratings: AC/DC.
New Super MK Relays.
MModels with Latching Lever Added to the Series G3FM-2R5SLN DC12.
Same mounting and internal wiring as the previous Super.
MK Relays.
Built-in mechanical indicator enables checking contact operation.
Two modes can be used to check circuits for models with latching lever OMRON G3FM-2R5SLN DC12.
Nameplate provided on models with latching lever.
All materials are RoHS compliant.
UL and IEC (TÜV) certification.