Classification: Relay with Auxiliary Contact Block.
Structure: 4 poles + 2 poles.
Contact configuration: Relay, 4PST-NO; Auxiliary Contact Block, DPST-NC.
Rated Voltage: 12, 24 VDC.
Compact Electromagnetic Contactors That.
Switch 40 A at 440 VAC.
One pole carries 40 A.
UL 508 and UL 840 NC contacts (resistive 40 A 480 VAC, 60 Hz, 80,000 operations).
EN 60947-4-1 NC contacts (AC1 40 A 440 VAC, 50/60 Hz, 80,000 operations).
Ideal for supply power to industrial inverters, servo drivers, and other devices,
and switching power to motors and other equipment.
The maximum load capacity of 160 A when using 4-pole parallel connections.
the Relay with an Auxiliary Contact Block.
Conforms to European PV standard (VDE0126).
Approx. 30% less operation noise than a standard electromagnetic contactor.
(Approx. 100 dB reduced to approx. 70 dB.)
Approx. 50% the volume of a standard electromagnetic contactor,
to help downsize control panels.
According to OMRON investigation of IIEC-AC1 50 A specifications.
Isolation: Photo-voltage coupler.
Zero cross function: No.
Indicator: Yes.
Rated output load: 0.5 A at 24 to 240 VAC, 0.5 A at 24 to 110 VDC.
Rated input voltage: 5 VDC.
100-A-max. Leakage Current, No Bleeder.
Resistor Required.
1 mA to 500 mA micro-load switching.
Switch to both AC and DC with no polarity G7Z-4A-02Z OMRON.
Switch for a wide range of voltages; 19.2 to 264 VAC, 19.2 to 125 VDC
G7Z-4A-02Z
Switch full- and half-wave rectifier AC loads.
Same sizes and terminal arrangements as OMRON Power,
Relay MY Series.
Operating indicator provided.
Switch MY Series (without bleeder resistor).
Superior surge absorption with a built-in varistor.
Optimum SSR to control minute load, valves, and solenoids G7Z-4A-02Z OMRON. Classification: Standard models.
Rated voltage: Standard products, 12, 24, 100/110, or 200/220 VAC,
12, 24, 48, or 100/110 VDC; Made-to-order items, 110/120 or 220/240 VAC.
New Latching Levers for Circuit Checking.
Added to Our Best-selling.
MY General-purpose Relays.
Now lead-free to protect the environment.
VDE certification (Germany).
Different colors of coil tape for AC and,
DC models to more easily distinguish them G7Z-4A-02Z OMRON.
MY(S) models with latching levers added for,
easier circuit checking. Compact Terminal SSR with 4 Outputs.
Easy-to-use SSR block that combines four compact G3S SSRs,
sockets, and heat sink in one unit.
Easy wiring with separate I/O terminal construction.
LED operation indicator.
Special socket used for easy Relay replacement.
Mounts either on DIN track or with screws. Classification: Models with built-in diode for coil surge absorption.
Contact configuration: 4 bifurcated.
Rated voltage: Standaard products, 24 VDC;
Made-to-order items, 12 or 48 VDC G7Z-4A-02Z.
New Latching Levers for Circuit Checking.
Added to Our Best-selling.
MY General-purpose Relays.
Now lead-free to protect the environment.
VDE certification (Germany).
Differeent colors of coil tape for AC and,
DC models to more easily distinguish them G7Z-4A-02Z.
MY(S) models with latching levers added for,
easier circuit checking.