Time specification: Instantaneous type.
Current setting range: 8 to 26 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
rent, open-phase, and reverse-phase.
ing the test button.
is indicated from the start of operation.
Space-saving, integrated construction.
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
Input voltage: 24 to 28 VDC.
Output voltage: 24 V.
Output current: 3.7 A/8 A (See note 2.).
DC Backup Block for S8TS Prevents 24-VDC.
Outages Due to Power Interruptions or Failures.
Supplies 24 VDC for a fixed period of time even during.
AC input outages to considerably improve system reliability OMRON K2CM-Q1L.
Block Power Supply Basic Block is connected using a Bus Line.
Connector to achieve a simple system configuration
K2CM-Q1L
Notification of alarms is provided by indications on the main unit.
and alarm signal output.
RoHS-Compliant. Shape: dip solder terminal.
Pole number: 40.
Pole pole number: 1.
Minimum packing unit: 50.
Printed board connector core, MIL specification standard.
Through the use of new productivity design, high reliability and low price synchronization OMRON K2CM-Q1L.
A box type plug (XG4C) which is convenient for saving space is provided in the province.
A press type plug (XG4E) capable of using the relay is provided.
Will be the company''s loose wire connector (XG5) - specific plug (XG8) and PCB type.
(XG2) combined use of various types of packaging can be achieved.
Suitable for the company''s own development of a simple locking lever can make the unique plug (XG8) and,
Box type plugs (XG4C) can also be locked OMRON K2CM-Q1L.
MIL specification (MIL-C-83503) standard.
Standard product conforms to the UL specification (No K2CM-Q1L OMRON. E103202 File) certified products. Power ratings: 120 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC)*1.
Output voltage: 24 V K2CM-Q1L OMRON.
Output current: 5 A.
Alarm output *2: Sinking.
UL Class 2 Output standards: --.
Model number(screw terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that K2CM-Q1L OMRON.
conform to UL Class 2 Outpput standards K2CM-Q1L.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 ((= VDE 0805 Teil 1) OMRON K2CM-Q1L.
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards.)