Action determine the color, can switch the green / Red 2 kinds of color display.
Rotary encoder and a variety of ON/OFF pulse signals, the most up to 50kHz of high-speed pulse measurement
Supply voltage: 12 VDC.
Control output: Contact output, DPDT (time-limit DPDT,
or time-limit SPDT + instantaneous SPDT) Changed using a switch.
Eight-mode Timer.
Multiple time ranges and operating modes let you cover a wide,
range of applications.
The time-limit DPDT output contacts can be changed to time-limit,
SPDT and instantaneous SPDT output contacts using a switch K3HB-RPB-L2AT11 AC/DC24V OMRON
K3HB-RPB-L2AT11 AC/DC24V
Sequence checks are easily performed by setting an instanta,
neous output to 0.
Start signal control for the H3DK-M. Operating modes: Flicker ON start.
Supply voltage: 100 to 240 VAC/100 to 125 VDC, 24 to 48 VAC/12 to 48 VDC.
0.05 s to 300 h models: 8-pin models.
DIN 48 × 48-mm Twin Timers.
Wide power supply ranges of High Voltage 100 to 240 VAC/100,
to 125 VDC and Low Voltage 24 to 48 VAC/12 to 48 VDC K3HB-RPB-L2AT11 AC/DC24V OMRON.
ON- and OFF-times can be set independently and so,
combinations of long ON- or OFF-time and short OFF- or ON,
time settings are possible.
Twenty-four time ranges from 0.05 s to 300 h depending on the,
model to be used.
Models with a flicker ON start or flicker OFF start are available.
Easy sequence checks through instantaneous outputs for a,
zero set value at any time range K3HB-RPB-L2AT11 AC/DC24V OMRON.
Length, when panel-mounted with a Socket, of 80 mm or less.
11-pin and 8-pin models are available. Input type: DC current input.
Output type: transistor; -; NPN open collector (HH, H, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC100 ~ 240V.
96 (W) * 48 (H * 95mm) some models are not equipped with depth.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trendd K3HB-RPB-L2AT11 AC/DC24V.
External event input can be applied to a variety of measurement and identification situations.
DeviceNetTimer input: PNP/NPN universal DC voltage input(4.5 to 30 VDC).
Display: 7-segment LCD.
Time range: 999999.9h ←→ 3999d23 K3HB-RPB-L2AT11 AC/DC24V. 9h(switchable); Black body.
Seven digits, time range 0 to 3999d23.9h.
Dual time range: 999999.9 ←→ 3999d23.9h or,
999h59m59s ←→ 9999h59.9m.