Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table.
Action determine the color, can switch the green / Red 2 kinds of color display.
External event input can be applied to a variety of measurement and identification situations.
Supply voltage: 100 to 240 VAC.
6-digit total counter: Light gray.
DIN 48 x 24-mm Total Counter/Time Counter,
with Easy-to-read Displays and Water and,
Oil Resistance Equivalent to IP66.
High-visibility, negative transmissive LCD display with 8.5-mmhigh characters and, built-in red LED backlight at low power K3HB-XAA-CPAC11 AC100-240 OMRON.
consumption.
IP66 with oil resistance and NEMA 4 protection achieved by,
unifying the front with the case and by using oil-resistant parts,
and materials
K3HB-XAA-CPAC11 AC100-240
Compact (80 mm) body.
Just change a switch setting for either an NPN or PNP input.
Supports both external resetting and manual resetting.
Finger-protection terminal block cover prevents electrical shock,
and conforms to VDE0106, Part 100 K3HB-XAA-CPAC11 AC100-240 OMRON.
Certified for UL and CSA safety standards.
Complies with EMC standards (EN 61326) and CE Marking. Category: external supply 100mA DC10V.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
Communication: RS-485; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V K3HB-XAA-CPAC11 AC100-240 OMRON.
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External eventsDIN 48 × 48-mm Twin Timers.
Wide power supply ranges of High Voltage 100 to 240 VAC/100,
to 125 VDC and Low Voltage 24 to 48 VAC/12 to 48 VDC.
ON- and OFF-times can be set independently and so,
combinations of long ON- or OFF-time and short OFF- or ON,
ttime settings are possible K3HB-XAA-CPAC11 AC100-240.
Twenty-four time ranges from 0.05 s to 300 h depending on the,
model to be used.
Models with a flicker ON start or flicker OFF start are available.
Easy sequence checks through instantaneous outputs for a,
zero set value at any time range K3HB-XAA-CPAC11 AC100-240.
Length, when panel-mounted with a Socket, of 80 mm or less.
11-pin and 8-pin models are available.