Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table.
Action determine the color, can switch the green / Red 2 kinds of color display.
External event input can be applied to a variety of measurement and identification situations.
Linear Sensor Indicator for High-speed, High,
precision Measurement and Discrimination.
Easy recognition of judgement results using color display that can be,
switched between red and green.
Equipped with a position meter that represents measured amounts and,
relative positions.
Develop a variety of measurement and discrimination applications us,
ing external event inputs OMRON K3HB-XAD-CPAC21 AC100-240
K3HB-XAD-CPAC21 AC100-240
Series expanded to include DeviceNet models.
Short body with depth of only 95 mm (from behind the front panel),
or 97 mm for DeviceNet models.
UL certification approval (Certification Mark License).
CE Marking conformance by third party assessment body.
Water-resistant enclosure conforms to NEMA 4X (equivalent to IP66) OMRON K3HB-XAD-CPAC21 AC100-240. Type: H7CX-R Series.
Classification: Tachometer.
Configuration: Tachometer.
External connections: 11-pin socket.
Settings: 1-stage(2 inputs and outputs).
Display digit: 6 digits.
Outputs: Contact output (SPDT + SPST).
Power supply voltage: 12 to 24 VDC/24 VAC.
Ultra-compact Counter Provides More,
Complete Functionality.
Basic Features.
Short body with depth of only 59 mm (for 12 to 24-VDC Models with,
Screw Terminals) OMRON K3HB-XAD-CPAC21 AC100-240.
Better readability with character height of 12 mm on 4-digit models,
and 10 mm on 6-digit models.
The present value display characters can be switched between red,
green, and orange K3HB-XAD-CPAC21 AC100-240 OMRON.
Safety and Reliability.
New set value limit and counter functions have been added.
Other Features.
Front Panel can be changed to white or light gray K3HB-XAD-CPAC21 AC100-240 OMRON.
New models with two tachometer inputs and two tachometer outputs have,
been added to the series. Supply voltage: 24 VDC.
Input type: DC voltage, DC current, or NPN input.
Output type: Judgement output, 2 relay contact outputs(SPST-NO);
Data transmission output, RS-485. K3HB-XAD-CPAC21 AC100-240.
1/32 DIN Digital Panel Meter for Downsizing K3HB-XAD-CPAC21 AC100-240 OMRON.
Equipment and Control Panels.
Compact size: 48 x 24 x 82 (W x H x D).
Multi-input compatible: DC voltage/current, rotary pulse.
Two display colors (switchable): green/red OMRON K3HB-XAD-CPAC21 AC100-240.
Selectable outputs.
CE marking and UL/CSA approval.
Splash-proof construction (NEMA4X: equivalent to IP66).