Measuring voltage: 20 to 200 V AC/DC, 30 to 300 V AC/DC, 60 to 600 V AC/DC.
Supply voltage: 200-230 VAC.
Ideal for voltage monitoring for industrial.
facilities and equipment.
Monitor for overvoltages or undervoltages.
Manual resetting and automatically resetting supported by one Relay.
One SPDT output relay, 6 A at 250 VAC (resistive load).
Output relay can be switched between normally open and normally closed.
Process control signal (0 to 10 V) and current splitter input supported.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply.
Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL).
Detect three-phase AC current for under and/or overcur,
rent using current converter OMRON K8AB-VS3 AC200/230V.
Available in 7 supply voltage configurations.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T)
K8AB-VS3 AC200/230V
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verse current detection.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F).
LED operation indicator.
UL/CSA approval (SDV-F@) OMRON K8AB-VS3 AC200/230V. Type: open type.
Structure: DIN guide rail mounting type.
Capacity: 15W.
Output voltage: 24V.
Output current: 0.65A.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity OMRON K8AB-VS3 AC200/230V.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
(except for the 300/600/1500W output terminals)
Support finger touch protection to prevent electric shock.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable when the fan is replaced by the customer.)
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)
Configuration: Covered Power Supplies.
Input voltage: 100 to 240 VAC (free) (80 to 370 VDC *).
S8JX-G15005@@:Switchable between 100 to 120 VAC and 200 to 240 VAC.
(DC power cannot be input.).
Power ratings: 150 W.
Output voltage: 24 V.
Output current: 6.5 A.
Built-in fan: No.
Easy-to-use, Widely range from 15 W to 600 W (Output Voltage: 5 V to 48 V).
Easy Mounting: Front-mounted type, DIN rail-mounted type are available.
Screw-mount at the top. (except 300-/600-W models).
Safety standards: UL 5088/60950-1, cUL CSA C22 K8AB-VS3 AC200/230V. 2 No. 107.1,
cUR CSA C22.2 No. 60950-1.
EN 50178 (= VDE 0160) Over voltage.
category III.
EN 60950-1 (= VDE 0805 Teil 1).
EMC: Conforms to EN 61204-3.
(EMI:EN55011 ClassA).
Input conditions: The inpuut voltage range of 15-W, 35-W,
50-W, 100-W, and 150-W models has,
been increased to 80 to 370 VDC (EC Directives and safety standards do not apply K8AB-VS3 AC200/230V. ).