LK166
Home >> Products >> MITSUBISHI >> L series PLC >> CPU and accessories >> CPU >> L02SCPU-CM MITSUBISHI L02SCPU-CM

L02SCPU-CM MITSUBISHI L02SCPU-CM

Brand: MITSUBISHI
Name: cpu module
Model: L02SCPU-CM
"Universal output function: leakage type.
Program capacity: 20K step.
Basic operations processing speed: 60ns.
Communication interface: USB/RS-232.
Control mode: stored procedure repeated operation.
Input / output points: 1024 points.
End cap.
Unable to install display module (L6DSPU-C-CM), RS-232 adapter, RS-422/485 adapter.
CPU built-in functions can be easily set through programming tools.
The built-in I/O function settings can be easily carried out through the parameters of the programming tool.
5 s units can be used for high precision workpiece measurement in pulse measurement mode,
Can be used with a minimum of 5 s units of the input signal of the ON/OFF time (the shortest 200 s) for high precision measurement.
For example, after measuring the ON time of the sensor input,
The "moving speed" and "length" of the workpiece can be accurately calculated ".
High precision PWM control of the highest 200kHz.
In the PWM output mode, by setting the ON time and cycle time,
The duty cycle can be changed, and the minimum cycle time is 5 s.
In addition to lighting dimming control, simple motor control and heater control,
Can also be used to require high resolution detection equipment, such as a wide range of oscillators. "

Can be isolated to obtain DC24/48/100V, AC100/200V input signal.CC-Link master / local station.
Transmission speed: 10Mbps.
Remote input / output: 8192 points.
Remote register: 2048 words.
Link points in Ver.2.0 CC-Link master station.
Using CC-Link to connect with multiple devices.
Rich device using open network CC-Link,
System can be constructed according to the control requirements MITSUBISHI L02SCPU-CM L02SCPU-CM
Support Ver.2.0 CC-Link,
So it can be effectively used in the field of large capacity data communication.
No need to set the transmission speed of the local station
Automatic tracking function of transmission speed
When used as a local station, the transmission speed of the master station can be automatically tracked,
Do not need to set up in the local station MITSUBISHI L02SCPU-CM.
The transmission speed of the operation can be confirmed by the positive LED of the module. Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.Output points: 8 points (independent of all points).
Rated output voltage: DC24V/AC240V.
Rated open and close current: 2A/1 point.
Public side mode: no public side (all points of independent contact) MITSUBISHI L02SCPU-CM.
Input / output occupied points: 16 points (I/O distribution: output 16 points).
External wiring connection: 18 point terminal.
The switch input and output module is a device which can collect the input / output of the switch signal,
Digital I/O modules are often called.
The switch signal is collected to the computer or the computer to send the relevant instructions through the RS-485 bus to control the switch of the switch,
Can also be carried out through the RS-485 bus communication,
Remote control switch.
Communication protocol is a standard Modbus protocol or custom protocol. Can be isolated to obtain DC24/48/100V, AC100/200V input signal.Can be isolated to obtain DC24/48/100V, AC100/200V input signal.Output points: 8 points.
Output form: no public side (all points independent).
Rated output voltage: AC100 ~ 240V.
Max load current: 1A/1 point.
Common way: no public side (all points of independence).
Input / output occupied points: 16 points (I/O distribution: output 16 points).
External wiring connection: 18 point terminal.
1, the switch quantity acquisition and switch control and RS-485 bus are isolated from each other, and isolated from the whole system.
2, the power supply line has anti reverse connect function, once the wrong power line,
Will automatically cut off the power to protect the entire module is not damaged.
With over-voltage protection function, when the voltage is too high, automatic disconnection,
Protecting the entire module is not damaged.
3, RS-485 interface with 600W lightning protection and surgge protection function, with 3000V photoelectric isolation L02SCPU-CM.
4, the use of Modbus protocol, good general, can be very convenient and other systems,
Customers can also according to their own personal needs, custom related agreements, convennient and flexible L02SCPU-CM.
5, communication lines using RS-485 bus, support for multiple modules in parallel use,
Easy to expand the system, good scalability.


...More relevant models >>>>