Note: when the order is ordered, the number of the models is added with the rated voltage of the coil.
Arc barrier equipped with high insulation strength (AC2000V).
Number of phases: Three-phase.
Insulation method: Phototriac coupler.
Operation indicator: Yes (yellow).
Rated input voltage: 12 to 24 VDC.
Zero cross function: Yes.
Type: DIN track mounting *2.
Applicable load: 45 A, 200 to 480 VAC.
Number of pole: 3.
Compact, Slim-profile SSRs with Heat Sinks OMRON LY2F-J.
Solid State Contactors for Three-phase.
Heaters Reduced Installation Work.
with DIN Track Mounting
LY2F-J
RoHS compliant.
Surge pass protection improved surge dielectric strength,
for output currents. (OMRON testing).
Slim design with 3-phase output and built-in heat sinks.
DIN Track mounting types and screw mounting types are available.
All DIN Track mounting types mount to DIN Track.
(applicable DIN Track: TR35-15Fe (IEC 60715)) OMRON LY2F-J.
Conforms to UL, CSA, and EN standards (TÜV certification). Number of elements: 3.
Insulation method: Phototriac.
Rated supply voltage: 12 to 24 VDC.
Input method: No-voltage input (open and short circuit input).
Applicable motor: 0.75 kW (2.4 A), 380 to 400 VAC.
Soft-start Function Starts Motors Smoothly,
and Economically.
The soft-start function allows a smooth startup of motors by,
holding down the starting current, and functions like an inverter OMRON LY2F-J.
Comply with UL, CSA, IEC, and JEM requirements.
Mount with screws or to DIN tracks.
Compact monoblock construction (W: 80 × H: 100 × D: 100 mm) LY2F-J OMRON.
with a heat sink.
Snubber circuit and varistor are built-in.
Operation indicator. Input terminals: Screwless clamp terminals (detachable) LY2F-J OMRON.
Isolation method: Phototriaccoupler.
Zero cross function: Yes.
Operation indicator: Yes.
Alarm output: 2 outputs (Heater Burnout Detection,
SSR Short-circuit Failure Detection).
Applicable load (See note.): 2 to 25 A, 200 to 480 VAC.
A New-concept SSR with Built-in.
Current Transformer LY2F-J OMRON.
Heater Burnout and SSR Short.
circuit Failure Detection.
Built-in Current Transformer (CT) helps reduce wiring steps.
Detects the burnout of any one of a group of heaters.
Detects the burnout off 3-phase heaters LY2F-J.
Detects SSR short-circuit failures.
Error detection level can be easily set with a switch.
Mounts to a DIN track or with screws.
Three types of input terminals available: M3 terminals,
screwless clamp termiinals (detachable), or compact slotted,
screw terminals (detachable) OMRON LY2F-J.
Certified for CSA and EN (TÜV).
The G3PF-2@@B-@@@ Series is UL certified.