Structure: Relays with Plug-in Terminals, With operation indicators.
absorption (DC coil specification only).
Number of poles: 2 Bifurcated.
Power-switching Compact.
General-purpose Relays.
compliant with the UL, CSA, and SEV safety.
Material Safety Act.
Equipped with an arc barrier for arc interruption.
Withstand voltages up to 2,000 V.
joined the series.
with the LR and VDE safety standards.
and 100/110 VDC).
VAC, 200/220 VAC and 100/110 VDC).
Number of phases: Three-phase.
Insulation method: Phototriac coupler.
Operation indicator: Yes (yellow).
Rated input voltage: 12 to 24 VDC.
Zero cross function: Yes.
Type: Screw mounting.
Applicable load: 35 A, 200 to 480 VAC.
Number of pole: 2.
Compact, Slim-profile SSRs with Heat Sinks.
Solid State Contactors for Three-phase LY2ZN-D2 OMRON.
Heaters Reduced Installation Work.
with DIN Track Mounting
LY2ZN-D2
RoHS compliant.
Surge pass protection improved surge dielectric strength,
for output currents. (OMRON testing).
Slim design with 3-phase output and built-in heat sinks.
DIN Track mounting types and screw mounting types are available.
All DIN Track mounting types mount to DIN Track.
(applicable DIN Track: TR35-15Fe (IEC 60715)) LY2ZN-D2 OMRON.
Conforms to UL, CSA, and EN standards (TÜV certification). Type: output module.
Insulation mode: three end two-way photoelectric switch.
Action indicator: there.
Zero crossing trigger function.
Applicable load of output: AC100 2A ~ 240V.
Input rated voltage: DC24V.
I/O solid state relay can be used for OMRON I/O type G7TC relay terminal.
Input and output composite input module, the output module is complete LY2ZN-D2 OMRON.
Can be used for I/O type P7TF terminal. Can also be mixed with the I/O type G7T relay.
Can check the working status of SSR through the action indicator.
Have access to UL, CSA standard certification of the series of products have also been series (-US type)Contact form: SPST-NO.
Type: Models with Built-in Operation Indicators.
Rated voltage: AC: 24, 100, 110, 120, 200, 220, 230, 240;
DC: 12, 24, 48, 110, 220.
MK-S-series Relays with DC-switching,
Models That Can Switch 220 VDC, 10 A,
(Resistive Load).
Switch a DC load of 220 VDC, 10 A (resistive load).
Models for AC Loads can switch 250 VAC, 15 A (resisttive load) LY2ZN-D2.
Lineup includes models with SPST-NO and SPST-NO/SPST,
NC contact forms.
Using a SPST-NO/SPST-NC contact form enables detecting,
contact welding. (When the NO contacts become welded, the,
NC contacts will maintain a minimum distance of 0 LY2ZN-D2. 5 mm.).
Models available with operation indicators and built-in test buttons.
RoHS compliant.
Standards: UL, IEC (TÜV certification).