Type: 18 point terminal.
Input points: 16 points.
Rated voltage: DC24V.
Input response time: 0 ~ 70ms.
Input format: common terminal / negative public end sharing.
External connection: 1 wire.
IE CC-Link field network remote equipment station. According to the equipment, more easily distributed input and output devices.
Can be connected to the expansion module, more convenient to expand the input and output points.
Support synchronous communication (using with simple motion control module).
According to the simple motion control module of the network (Master) control cycle of the implementation of the control cycle and its synchronization,
Implementation of multiple simultaneous action from the station.
Type: sensor connector (e-CON).
Output form: transistor output, source.
Output points: 16 points.
Rated input voltage / current: DC12/24V (0.5A).
External connection: 3 wire.
By using the output ON number of times, it is convenient to confirm the total number of ON of each output point.
High speed input and output control of a single module can be realized by using first order logic function MITSUBISHI NZ2GF2B1-16D
NZ2GF2B1-16D
IE CC-Link field network remote equipment station. According to the equipment, more easily distributed input and output devices.
Can be connected to the expansion module, more convenient to expand the input and output points.
Support synchronous communication (using with simple motion control module).
According to the simple motion control module of the network (Master) control cycle of the implementation of the control cycle and its synchronization,
Implementation of multiple simultaneous action from the station MITSUBISHI NZ2GF2B1-16D. Type: 40 pin (FCN) connector.
Input / output form: differential input /DC input, uniform output: transistor output (drain type).
Number of channels: 2 channels.
Maximum 8Mpps count can be carried out MITSUBISHI NZ2GF2B1-16D. Using PWM output function, can achieve 0.1 s units of the very fine output control.
With the measurement resolution of 100ns, the measurement of the pulse width can be used to measure the pulse width.
IE CC-Link field network remote equipment station. According to the equipment, more easily distributed input and output devices.
Can be connected to the expansion module, more convenient to expand the input and output points.
Support synchronous communication (using with simple motion control module).
According to the simple motion control module of the network (Master) control cycle of the implementation of the control cycle and its synchronization,
Implementation of multiple simultaneous action from the station. Type: 18 point terminal.
Input / output form: temperature resistance input, transistor output, channel insulation.
Number of stations: 1 stops.
Number of channels: 4 channels.
Sampling period is 250ms/4 channel. Use 1 sets of temperature control module,
Can achieve standard control (heating, cooling) and heating cooling control.
This module has the functions of heating up, maximum current suppression, self diagnosis and so on.
IE CC-Link field network remote equipment station. According to the equipment, more easily distributed input and output devices.
Can bbe connected to the expansion module, more convenient to expand the input and output points NZ2GF2B1-16D.
Support synchronous communication (using with simple motion control module).
According to the simple motion control module of the network (Mastter) control cycle of the implementation of the control cycle and its synchronization,
Implementation of multiple simultaneous action from the station NZ2GF2B1-16D.