Contact form: SPST-NO.
Type: Models with Test Button and Built-in Operation Indicators.
DC: 12, 24, 48, 110, 220.
(Resistive Load).
Switch a DC load of 220 VDC, 10 A (resistive load).
Models for AC Loads can switch 250 VAC, 15 A (resistive load).
NC contact forms.
contact welding. (When the NO contacts become welded, the,
NC contacts will maintain a minimum distance of 0.5 mm.).
Models available with operation indicators and built-in test buttons.
RoHS compliant.
Standards: UL, IEC (TÜV certification).
Terminal (Wire connection): Push-In Plus Terminal.
Classification: Microloads.
Latching lever (Test switch): No.
Rated input voltage: AC, 200V.
Global standard size, low profile slim.
I/O relay with width 6.2 mm.
Realized about 25% lower profile than conventional.
products, contributing to further miniaturization of the control panel MKS1XTIN-10 OMRON.
Realized opening and closing ability with one pole 6 A slim shape
MKS1XTIN-10
Micro load products for one pole 50 mA using Au-plated.
contacts for small load switching also available.
Since G2RV is a transparent case, confirming the state of,
the contact with the naked eye is possible, and easy to,
confirm abnormality on-site (installed location).
Screw terminal is also stocked to meet the screw type needs MKS1XTIN-10 OMRON.
Mounted relay uses plug-in terminals that are difficult to,
bend when exchanging. Terminal (Wire connection): Screw terminal.
Classification: Microloads.
Latching lever (Test switch): No.
Rated input voltage: AC, 100V.
Global standard size, low profile slim.
I/O relay with width 6.2 mm.
Realized about 25% lower profile than conventional MKS1XTIN-10 OMRON.
products, contributing to further miniaturization of the control panel.
Realized opening and closing ability with one pole 6 A slim shape.
Micro load products for one pole 50 mA using Au-plated.
contacts for small load switching also available.
Since G2RV is a transparent case, confirming the state of,
the contact with the naked eye is possible, and easy to,
confirm abnormality on-site (installed location).
Screw terminal is also stocked to meet the screw type needs.
Mounted relay uses plug-in terminals that are difficult to,
bend when exchanging. Standard certification: No.
Action indicator: there.
Applicable load of output: AC100 3A ~ 240V.
Input rated voltage: DC5V.
Insulationn mode: three end two-way photoelectric switch MKS1XTIN-10.
Zero trigger function: No.
And the MY type of the same shape of the G3F series of new international standard certification (-VD type).
Achieved UL, CSA, EN (VDE certification) standard ccertification MKS1XTIN-10. (type -VD)
Socket terminal type of same size with MY (2 pole type).
A model with an action indicator to check the status of the input.