Mechanically Latching Relays Based on the.
MM Power Relay.
Low power consumption due to mechanical latch for economic operation.
(e.g., AC setcoil and DC reset coil).
Operational response fast enough to enable pulse signal power applications.
Ambient operating temperature: –10°C to 55°C.
Classification: Equipped with operation indicator and diode to absorb coil surge.
Contact form: 4PST (standard).
Mounting method: Screw mounting .
Terminals: Connector.
Rated voltage: 5 VDC, 12 VDC, 24 VDC.
Compact Terminal Relay with 4 Independent.
Outputs.
Equipped with four G6B Mini-relays that are compact, highly sen,
sitive, and highly resistant to dielectric surges, and that can switch,
5 amps of power OMRON MMK Series
MMK Series
Sealed plastic construction used for relays.
Easy wiring with separated input/output terminals.
Special P6B Mounting Socket used to facilitate maintenance,
(except for high-reliability models).
UL and CSA certification for standard models,
(except for high-reliability models) OMRON MMK Series.
VDE certification for G6B-4BND/47BND/48BND for 12/24 VDC.
DIN Track mounting, and screw mounting models are available. Isolation: Photocoupler.
Zero cross function: Yes.
Indicator: Yes.
Rated output load: 5 A at 100 to 240 VAC.
Rated input voltage: 5 to 24 VDC.
International Standards for G3B Series,
Same Profile as MK Power Relays.
Shape-compatible with mechanical relays.
Certified by UL, CSA, and VDE (models numbers with a suffix of “-VD”) OMRON MMK Series.
Plug-in type, same size as MK Power Relays.
Operation indicator provided to confirm input.
DC Output model available with 3 to 125-VDC load voltage,
range for high-voltage applications MMK Series OMRON. Type: Standard.
Contact form: 4PDT.
Open structure: Solder terminals.
Mechanically Latching Relays Based on the.
MM Power Relay MMK Series OMRON.
Low power consumption due to mechanical latch for economic operation.
Relays with mixed coil specifications can be produced,
(e.g., AC setcoil and DC reset coil).
Operational response fast enough to enable pulse signal power applications.
Ambient operating temperature: –10°C to 55°C. Number of elements: 3 MMK Series OMRON.
Insulation method: Photocoupler.
Rated supply voltage: 100 to 240 VAC.
Applicable motor: 2.2 kW (11.1 A), 200 to 220 VAC. MMK Series.
Solid State Contactors That Can Drive 3-phase Motors Frequently,
and Achieve Harmonized Protection with Thermal.
Overload Relays.
Certified for UL and CSA.
Mount with screws or to DIN tracks.
Compact monoblock construction ((W: 80 × H: 100 × D: 100 mm) OMRON MMK Series.
with a heat sink.
Snubber circuit and varistor are built-in.
Operation indicator.
Two-element models added to series.