LK166
Home >> Products >> OMRON >> Relay >> General relay >> Relay for control cabinet >> MY4N-GS AC24 OMRON MY4N-GS AC24

MY4N-GS AC24 OMRON MY4N-GS AC24

Brand: OMRON
Name: Miniature power relay
Model: MY4N-GS AC24
Action indicator: LED action indicator, mechanical indicator.
Number of contacts: 4 pole.
Operating coil voltage: AC24V.
Universal relay the best-selling MY standard mechanical indicator, can confirm the action state contact.
According to the LED action indicator light color, can identify the AC coil specifications, DC coil specifications.
Online lap tape printing operation coil specifications, the recognition is higher.
All standard specifications indicating mechanism of mechanical action (mechanical indicator).
Suitable for environmental protection RoHS.
Conforms to the UL, CSA, IEC (VDE) standard

Number of phases: Three-phase.
Insulation method: Phototriac coupler.
Operation indicator: Yes (yellow).
Rated input voltage: 12 to 24 VDC.
Zero cross function: Yes.
Type: DIN track mounting *2.
Applicable load: 25 A, 100 to 240 VAC.
Number of pole: 3.
Compact, Slim-profile SSRs with Heat Sinks OMRON MY4N-GS AC24.
Solid State Contactors for Three-phase.
Heaters Reduced Installation Work.
with DIN Track Mounting MY4N-GS AC24
RoHS compliant.
Surge pass protection improved surge dielectric strength,
for output currents. (OMRON testing).
Slim design with 3-phase output and built-in heat sinks.
DIN Track mounting types and screw mounting types are available.
All DIN Track mounting types mount to DIN Track.
(applicable DIN Track: TR35-15Fe (IEC 60715)) OMRON MY4N-GS AC24.
Conforms to UL, CSA, and EN standards (TÜV certification). Standard certification: No.
Insulation: photo coupler.
Zero crossing trigger function.
Action indicator: No.
Applicable load of output: AC100 3A ~ 240V.
Input rated voltage: DC4 ~ 24V.
With the LY1, LY2 large power relay with the same shape of the G3H series, the new international standard certification (-VD type) OMRON MY4N-GS AC24.
Achieved UL, CSA, EN (VDE certification) standard certification. (type -VD)
Socket terminal type of same size with LY (1 pole, 2 pole type).
A model with an action indicator to check the status of the input. (type N)Number of elements: 3.
Isolation method: Phototriac coupler.
Rated powersupply voltage: 12 to 24 VDC.
Input method: No-voltage input (open and short circuited input).
Applicable monitor capacity (AC3): 3.7 kW (17.4 A), 200 to 220 VAC.
Monitor output: DC switching ooutput MY4N-GS AC24.
New Models with AC Power Supply Input and,
Monitor Output Equivalent to Non-contact,
SPST-NO Join the G3J-T Series,
Limiting the starting current saves energy.
Certified for UL and CSA.
Mounts with screws or to DIN Track.

Compact design with heat sinks (3 MY4N-GS AC24. 7-kW models: 100 × 100 ×130 mm (W × H × D)).
Built-in snubber circuit and thyristor.
Built-in operation indicator.


...More relevant models >>>>
Related download