LK166
Home >> Products >> MITSUBISHI >> Ans/QnAs series PLC >> Ans/QnAs series accessories >> Memory card Q1MEM-512SE MITSUBISHI Q1MEM-512SE

Memory card Q1MEM-512SE MITSUBISHI Q1MEM-512SE

Brand: MITSUBISHI
Name: Memory card
Model: Q1MEM-512SE
SRAM+E2PROM memory card.
RAM capacity: 256KB.
E2PROM capacity: 256KB.

Input type: AC.
Input points: 16 points.
Input voltage: AC200-240V.
Input current: 11mA.
Connection mode: terminal row.
Common common point: 16.
The instruction list programming language is a programming language similar to assembly language mnemonic,
As well as assembly language by the operation code and the number of operations MITSUBISHI Q1MEM-512SE.
In the case of the computer for the PLC handheld programmer compile user program Q1MEM-512SE
At the same time, the programming language of the instruction list corresponds to the ladder diagram programming language,
In PLC programming software can be converted to each other. Figure 3 is the instruction sheet corresponding to the ladder diagram of figure 2PLC.
The characteristics of instruction table programming language is used to represent mnemonic operation function,
Easy to remember, easy to grasp;
In the handheld programmer on the keyboard using the mnemonic representation, easy to operate, can be programmed in computer;
There is a one-to-one correspondence between the ladder diagram and the ladder diagram MITSUBISHI Q1MEM-512SE. Its characteristics are basically consistent with the ladder diagram language MITSUBISHI Q1MEM-512SE. 32: terminal line adapter 0.75mm2 (AGW18).3C-2V/5C-2V coaxial cable between double loop PC (control station / common station) / remote I/O network (remote master station).
The response time of PLC is the interval between the time of the change of the external output signal of the PLC and the time of the change of the external output signal which is controlled by it,
Lag time, this is the time constant of the input circuit,
The time constant of the output circuit, the arrangement of the user statement and the use of the instruction,
The cycle scan mode of PLC and the way of PLC to refresh the I/O and so on Q1MEM-512SE MITSUBISHI Q1MEM-512SE MITSUBISHI.
This phenomenon is called the I/O delay time effect Q1MEM-512SE MITSUBISHI.
Switch volume control is designed to,
According to the current input combination off the switch quantity and the history of the input sequence,
So that PLC generates the corresponding switching output,
In order to make the system work in a certain order Q1MEM-512SE.
So, sometimes also known as the order control.
And seqquential control is divided into manual, semi-automatic or automatic MITSUBISHI Q1MEM-512SE.
And the control principle is decentralized, centralized and hybrid control three.


...More relevant models >>>>