Function name: 3 phase 400V.
Power: 11KW.
Rated output voltage: 3 phase, 380 ~ 480V (the output voltage can not exceed the input voltage).
Built in brake unit (brake resistance needs to be matched).
Weight: 4.7KG.
Dimension (w * h) 296mm *:180.
Outline dimension (deep):175mm.
Mechanical automation concept.
Positioning function.
The use of options.
(EtherCAT, CompoNet and DeviceNet) to realize the field bus communication.
Driver programming function.
Current vector control.
High starting torque: 0.5Hz up to 200%.
Safety features, in compliance with ISO13849-1:2008 EN (Cat.3/PLd) and IEC60204-1 stop level 0 standard.
Frequency output up to 580H.
When the power supply capacity exceeds the power supply capacity of the inverter or the need to improve the power factor, it is required to connect the AC reactor.
Please according to the maximum capacity of heavy load and light load rated conditions suitable for motor to select option. The communication unit can connect the multi function small transducer EtherCAT to the MX2 network OMRON 3G3MX2-A4110-ZV1
3G3MX2-A4110-ZV1
The communication unit passed the EtherCAT conformance test.
Power supply: through the inverter power supply.
Protection structure: open type (IP20). Specification: three phase 400V.
Power: 132KW.
Maximum output voltage: three phase AC380 ~ 480V (input voltage correspondence).
Rated voltage: three phase 480V ~ 50/60Hz AC380 OMRON 3G3MX2-A4110-ZV1.
Weight: about 120kg.
In the inverter is equipped with the servo can play the same static torque with PG vector control function,
DeviceNet communication makes the application field more extensive.
The high functional specifications are concentrated in the compact.
Equipped with PG vector control.
Subsequent models of 3G3RV.
CV/VT selection function.
Rich online automatic adjustment function (self learning function) OMRON 3G3MX2-A4110-ZV1.
CX-Drive software.
DeviceNet correspondence correspondence.
Multi function input and output function.
Colorful function.
Brake transistor built-in.
Protection function. Power supply: 3 phase 3 line rated voltage 500V AC.
Rated current: 25A.
Weight: 2.1KG.
Used to reduce the noise generated by the inverter.
Try to be close to the transducer for connection. Cable length: 3m.
A digital operator is installed in a place far away from the transducer. Function name: 3 phase 400V.
Power: 5.5KW.
Rated output voltage: 3 phase, 380 ~ 480V (the output voltage can not exceed the input voltage).
Built in brake unit (brake resistance needs to be matched).
Weight: 3.5KG.
Dimension (w * h) 260mm *:140.
Outline dimension (deep)::155mm 3G3MX2-A4110-ZV1.
Mechanical automation concept.
Positioning function.
The use of options.
(EtherCAT, CompoNet and DeviceNet) to realize the field bus communication.
Driver programming function.
Current vector control.
High starting torque: 00 3G3MX2-A4110-ZV1. 5Hz up to 200%.
Safety features, in compliance with ISO13849-1:2008 EN (Cat.3/PLd) and IEC60204-1 stop level 0 standard.
Frequency output up to 580H.