For C200H-PRO27-E Hand-held Programming Console ming Console.
Name: Temperature Control Module.
Model: C200H-TC001.
Sensor: Thermocouple: R, S, K(CA), J(IC), T(CC), E(CRC), B, N, L(IC), U(CC).
Control output: Transistor outputA memory card suitable for Phoenix PCM+3.2 and one of thefollowing Bus Connection Units is required. No PC card is provided with the Unit OMRON C200H-CN521. Name: Host Link Module.
Model: C200H-LK201-V1.
Communication ports: 1 RS-232C, 25 pin female
C200H-CN521Model: C200H-MD501.
No. of I/O pts: 16 inputs, 16 outputs.
Specifications: 5 VDC.Model: C200H-B7AI1.
I/O points: 16 points or 15points and 1 error input
Weight: 200g max.100 to 120/200 to 240 VAC (Supports SYSMAC LINK and SYSMAC NET Link Systems.)Name: Space Module.
Model: C200HW-CLK21.
Space Module: For I/O Module slots OMRON C200H-CN521. 24 VDC.Model: C200H-MR433.
Description: RAM, 4K words, battery back-up.with clock (CPU21, CPU23 only).Name: Cam Positioner Module.
Model: C200H-CP114.
Output points: 48 points (16 external output points, 32 internal output points).
External outputs: NPN transistor open collector (withphoto-coupler insulation)
Switching capacity: 100 mA at 24 VDC Simultaneous OName: Position Control Module OMRON C200H-CN521.
Model: C200HW-NC113.
Control method: Open-loop, automatic trapezoid acceleration/deceleration.
Control output sig-nals: Pulse-train outputs.
Controlled axes: 1.Name: Wired Master.
Model: C200H-RM201.UM: 31.2K words.
DM: 6K words.
EM: 6Kx3 banks(18K) words.
Instruction processing time (basic instructions): 0.1 µ.s min.
No. of I/O points: 880 points.
Max. no.of con-necting Expansion I/O Racks: 2 Racks.
Max. no. of connecting High-density I/O Units(i.e., Group-2): Unavailable.
Max. no. of con-necting Special I/O Units: 10.
RS-232C: NO.Model: C200H-ID216.
No. of points: 64 pts.
Specifications: 24VDC.
Weight: 180g max.Power supply voltage: DC100V.
Note: operation with output contacts.
Power supply unit.
The power supply of the CPU rack is supplied by the power supply unit.
The following power units are available for selection.
C200HW-PA204 (voltage: AC100-120V/AC200-240V)
C200HW-PA204S (voltage: AC100-120V/AC200-240V)
C200HW-PA204R (voltage: AC100-120V/AC200-240V)
C200HW-PD024 (voltage: DC24V)
In the past, PC connected tto a measurement equipment or components must be given to the ASCII unit or BASIC unit to write a communication program C200H-CN521.
Now, PC C200HX/HG/HE is installed on the communication protocol macro function,
Can be configured to these communicaations procedures through the PMCR instruction to the ladder program,
With this function system can be easily connected with a wide range of components C200H-CN521.