Name: e-CON Connectors.
Disconnected Line Detection.
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
wiring in the system.
contribute to system size reduction.
helps to detect errors on site.
content of the error.
Classification: For output.
Internal I/O circuit common: NPN (– common).
I/O points: 8 output points.
Connector Connection Models that.
Allows Easy Connection to Sensors and Output Devices.
Sensors with easy-to-wire connectors are easily,
attached or detached.
Connects to 2-wire sensors.
Remote teaching of the Sensor Terminal is possible OMRON CRT1-OD16SH-1.
with the PLC by using output signals of the Sensor Terminal
CRT1-OD16SH-1
DIN track mounting and screw mounting are available. Specifications: Inputs, PNP (- common), 16 points.
I/O connections: Sensor I/O connector.
Rated internal circuit power supply voltage:
Supplied from the communications. connector.
Rated I/O power supply voltage: 24 VDC.
Remote I/O Terminals with High OMRON CRT1-OD16SH-1.
Degree of Environmental Resistance.
(IP67) in Product Lineup Including.
Economical Input, Output, and Mixed I/O Models.
Common Smart Slave functionality provides strong support for equipment,
operation status monitoring and effective maintenance.
High degree of environmental resistance with dust-proof and drip-proof,
construction. (IP67)
Models with one connector for two outputs are available to make easier,
connection with hydraulic valve devices OMRON CRT1-OD16SH-1.
(Models with 16 outputs and models with 16 mixed I/O)Short/disconnection detection: Supported.
Specifications: I/O, NPN (input: + common, output: - common), 16 inputs/16 outputs.
I/O connections: Clamp terminals.
Rated internal circuit power supply voltage:
Supplied from communications connector.
Rated I/O power supply voltage: 24 VDC.
Reduced Wiring and Labor on Factory Sites with Screw-less Terminal Wiring.
Screw-less structure eliminates tightening work.
Detachable terminal blocks for easier maintenance.
Single-step wiring by simply inserting pole terminals. Specifications: I/O, NPN (input: + common, output: - common),, 16 inputs/16 outputs CRT1-OD16SH-1.
I/O connections: MIL connector.
Rated internal circuit power supply voltage:
Supplied from communications connector.
Rated I/O power supply voltage: 24 VDC.
First Board-type Terminals for Smart Slaves!
Easiily modified to handle an array of I/O interfaces,
and eliminates much on-site wiring CRT1-OD16SH-1.
User boards attach easily to the DRT2-@D32BV(-1) using screws.