Actuator: Plunger.
Conduit size: 2-conduit; G1/2.
Built-in switch mechanism: 2NC/1NO (Slow-action).
A Series of Pull-reset Models Now.
Available.
contact forms in addition to the previous contact forms 1NC/1NO and 2NC.
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115, EN81-1 and EN81-2.
Certified standards: UL, EN (TÜV), and CCC.
Actuator: Fork lever lock (right operation).
Conduit size: 1-conduit; M20.
Built-in switch mechanism: 2NC/1NO MBB (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms OMRON D4N-6C31R.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement
D4N-6C31R
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Actuator: Roller lever (resin lever, resin roller) OMRON D4N-6C31R.
Conduit size: 1-conduit; M12 connector.
Built-in switch mechanism: 1NC/1NO MBB(Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement OMRON D4N-6C31R.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Name: Safety I/O Terminals.
No. of I/O points: Safety inputs: 8, safety outputs (semiconductor): 8,
test outputs: 4.
Distributed Safety Terminals That.
Reduce Wiring.
Lineup includes four models to accommodate various,
I/O types and number of I/O points.
Monitor the safety system from Standard Controllers,
across the network.
EN954-1 (Cat.4), ISO13849-1 (PLe),
and IEC 61508 SIL3 certification.
The DST1-XD0808SL-1 also supports logic operation,
functions for high-speed processing in applications,
requiring partial stopping of the safety system. Type: 2-Conduit.
Contact configuration: Slow-action; 2NC.
Conduit opening/Connector: G1/2.
Multi-contact, Labor-saving,
Environment-friendly, Next,
generation Safety-door Switch.
Lineeup includes three contact models with 2NC/1NO,
and 3NC contact forms and MBB models in addition,
to the previous contact forms 1NC/1NO, and 2NC D4N-6C31R.
M12-connector models are available, saving on,
labor and simplifying replacement.
Standaardized gold-clad contacts provide high,
contact reliability D4N-6C31R.
Applicable to both standard loads and microloads.
Variety of metallic heads available.