Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 3.2 dia.
Protective tubing length L: 20cm.
Lead wire type: Heat resistive.
Lead wire length M : 4m.
A Wide Variety of High-precision.
Temperature Sensors.
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
and also according to the type and shape of the terminal.
Size: DIN 1/8, 48 x 96 x 60mm.
Power supply voltage: AC100 ~ 240V.
Input type: thermocouple.
Alarm points: 1 points.
Control output: voltage output (for driving SSR).
Simple new temperature controller, easy to achieve temperature control.
Good visibility (character height E5CSL:21.7mm, E5CWL:16.2mm (PV), E5EWL:20mm (PV)) OMRON E52-CA20AY D=3.2 NETU 4M.
From the front panel depth: 60mm.
Parameter is less, set simple
E52-CA20AY D=3.2 NETU 4M
Sampling time was reduced to 250ms. Name: Basic Unit (temperature control) *1.
Power supply voltage: 24 VDC supplied from the End Unit.
No. of control points: 2.
Control outputs 1 and 2: Voltage output: 2 points (for SSR drive) *2.
Control outputs 3 and 4: Transistor output: 2 points (sinking).
Auxiliary output: None OMRON E52-CA20AY D=3.2 NETU 4M.
Functions: burnout Heater alarm, 2 *3; Event inputs, 2 .
Communications functions: G3ZA connection port: RS-485,
From End Unit: Port A or port B: RS-485.
Input type: Thermocouple, platinum resistance thermometer,
analog voltage, and analog current selectable for each channel.
Terminal: M3 terminal.
In-panel Temperature Controller with Flexible,
Modular Design and Wide Integration with Host,
Devices OMRON E52-CA20AY D=3.2 NETU 4M.
The compact modular structure enables construction of temperature,
systems optimally suited to the application.
Connection can be made to a Programmable Controller without any,
programming required, reducing the number of steps required in ladder,
programming design.
One fully universal-input Unit includes a thermocouple, platinum-resistance,
thermometer, and analog input for easy selection and reduced inventory,
requirements.
Connect directly to the G3ZA Multi-channel Power Controller using,
optimum cycle control for high-accuracy regulation with minimal noise.
Autotuning (AT) can be used for independent heating/cooling PID control.
Self-tuning (ST) can be used to calculate the PID constants with the step,
response method.
Up to 16 Temperature Controllers can be connected to a single DeviceNet,
Communications Unit. Protective tubing diameter: D = 8.0.
Sleeve diameter Sleeve length: d = 11mm, l = 55mm.
tube thickness: 0.8 mm.
Lead wire length: 0.5m.
A Wide Variety of High-precision.
Temperature Seensors E52-CA20AY D=3.2 NETU 4M.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Teemperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E52-CA20AY D=3.2 NETU 4M.