Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 6.4 dia. .
Protective tubing length L: 50cm.
Lead wire type: Standard.
Lead wire length M : 4m.
A Wide Variety of High-precision.
Temperature Sensors.
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
and also according to the type and shape of the terminal.
Terminal type: Exposed-lead Models.
Protective tubing diameter D(mm): 3.2 dia.
Protective tubing length L: 50 cm.
Lead wire type: Standard.
Lead wire length M: 1m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work OMRON E52-CA50AY D=6.4 4M.
Ideal for the thermal input devices of Temperature Controllers
E52-CA50AY D=6.4 4M
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Size: 96 × 96 mm.
Control type: Basic control (1 loop).
Control mode: 1 loop for standard control,
Single-loop heating and cooling control OMRON E52-CA50AY D=6.4 4M.
Outputs(control/transfer): 4 points: Pulse voltage and Pulse,
voltage/current and Current (2 points).
Optional functions: Auxiliary outputs (SUB), 4;
Event inputs, 2; Serial communications, Yes.
E5AR Digital Controllers offer high speed,
high precision, and multiple I/O and use a 5-digit,
3-row LCD display for high visual clarity.
A short sampling period of 50 ms enables use in applications,
requiring high-speed response OMRON E52-CA50AY D=6.4 4M.
PV, SP, and MV data is displayed simultaneously in a 3-row,
negative LCD display with a backlight.
Multiloop control, cascade control, and proportional control are,
possible with a single Controller.
When using models with CompoWay/F communications, initial,
settings can be downloaded and settings can be masked using,
Support Software (CX-Thermo version 4.0 or higher).
Equipped with calculation functions as a standard (e.g., square,
root calculation and broken-line approximation).
DeviceNet Communications.
Data setting and monitoring can be performed without special programming. Size: 1/4 DIN 96 × 96 × 78 (W × H × D).
Power supply voltage: 100 to 240 VAC.
Input type: Thermocouple or Resistance thermometer.
Alarm output: 3.
Control output: Voltage output(for driving SSR).
Functions: Heater burnout, Yes (CT1); Mounting option units, Yes.
Previous model: E5AZ-Q3 + E53-AZM + E53-AZ.
These Best-selling General,
purpose Temperature Controllers,
Are Now Even Better.
Controllers now available with analog inputs.
Faster samplingg at 250 ms E52-CA50AY D=6.4 4M.
Transfer output provided for easy output to recorders.
Models available with a loop break alarm (LBA) and,
heater short alarm (HS alarm).
Manual output provided.
Easy setting with 11-segment displays.
New protoocol called Modbus is installed in the,
models with communications E52-CA50AY D=6.4 4M.
USB-Serial conversion cable is available.
Note: Refer to Precautions on page 33.