Size: 1/16 DIN 48 × 48 × 78 (W × H × D).
Power supply voltage: 100 to 240 VAC.
Input type: Analog (current/voltage).
Alarm output: 2.
option units Mounting: Yes.
Control output: Current output.
Previous mode: None.
Is Now Even Better.
Controllers now available with analog inputs.
Faster sampling at 250 ms.
Transfer output provided for easy output to recorders.
heater short alarm (HS alarm).
Easy setting with 11-segment displays.
protection is enabled.
Manual output provided.
with communications.
USB-Serial conversion cable is available.
Note: Refer to Precautions on page 33.
Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 4.8 dia.
Protective tubing length L: 50 cm.
Lead wire type: Standard.
Lead wire length M : 4m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work OMRON E5CZ-C2ML.
Ideal for the thermal input devices of Temperature Controllers
E5CZ-C2ML
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Size: 48 x 96mm.
Type: thermocouple type.
Adjustment mode: ON/OFF action or PID action.
Alarm: single alarm OMRON E5CZ-C2ML.
Output: relay output.
Temperature controller with single alarm output.
SV and PV can be displayed at the same time.
Multiple temperature range allows setting the optimum temperature range.
The protection function can prevent the error in operation. Element type: K (CA).
Terminal type: Exposed-terminal Models.
Protective tubing diameter D (mm): 15 dia.
Protective tubing length L: 35 cm.
A Wide Variety of High-precision OMRON E5CZ-C2ML.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Case color: Black.
Control output: Relay output.
Control mode *1: Standard.
No. of auxiliary outputs: --.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, E5GN-RTC;
Resistance thermometer input, E5GN-RP.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the staatus of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E5CZ-C2ML.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs E5CZ-C2ML.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.