Name: Basic Unit (temperature control) *1.
Power supply voltage: 24 VDC supplied from the End Unit.
No. of control points: 2.
Control outputs 1 and 2: Current output: 2 points.
Control outputs 3 and 4: Transistor output: 2 points (sinking).
Auxiliary output: None.
Functions: burnout Heater alarm, None; Event inputs, 2.
From End Unit: Port A or port B: RS-485.
analog voltage, and analog current selectable for each channel.
Terminal: M3 terminal.
Devices.
systems optimally suited to the application.
programming design.
requirements.
optimum cycle control for high-accuracy regulation with minimal noise.
Autotuning (AT) can be used for independent heating/cooling PID control.
response method.
Communications Unit.
Size: 96 x 96mm.
Ontology: terminal type, analog input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
The heater is used to break, SSR fault, heater over current detection function /ES1B power supply: single phase or three phase heater with detection function OMRON EJ1N-TC2A-CNB
EJ1N-TC2A-CNB
Event entry point: 4.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance OMRON EJ1N-TC2A-CNB.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation OMRON EJ1N-TC2A-CNB.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation. Size: 96 x 96mm.
Control output 1: linear current output.
Control output 2:--.
Auxiliary output: 2 independent points.
Power supply voltage: AC/DC24V.
Terminal shape: screw terminal table type.
Input category: full range multi input.
Heating wire break, SSR fault detection function: -.
Communication: -.
Event input: 6 points.
Remote SP input: there.
Transfer output: have.
Large screen display white PV legible. From selection to setting and operation are simple and easy to use.
Full capacity, function and performance of I/O. Suitable for more applications.
E5AC white LCDPV display height is about 25mm.
The upper panel and the front panel are equipped with tool ports.
With the communication conversion line (sold separately) connected to the computer to establish the controller without the need to install the wire for power supply.
Easy to install CX-Thermo (sold separately).
50ms high speed sampling period.
Model can be equipped with up to 4 point auxiliary output, 6 point event input,
1 point transfer output and remote SP input, suitable for a wide range of applications EJ1N-TC2A-CNB.
The main body is short, the thickness is only 60mm.
Easy to use programmable logic controller (PLC) is connected to the programmable logic controller (PLC).
The temperrature controller is connected to each other by using the component communication EJ1N-TC2A-CNB.
A new type of proportional control allows you to control the valve.