Isolation: Phototriac coupler.
Zero cross function: NO.
Indicator: Yes.
Rated output load: 3 A at 100 to 240 VAC *1.
Rated input voltage: 12 VDC.
New Models with International Standards.
Added to G3H Series (-VD in model number).
Same Profile as LY1 and LY2 Bi-power.
Relays.
Certified by UL, CSA, and VDE (models numbers with a suffix of “-VD”).
Socket type, same size as LY Power Relays.
(models numbers with “N” before the suffix).
Isolation: Phototriac.
Zero cross function: Yes.
Indicator: No.
Rated output load: 5 A at 100 to 240 VAC.
Rated input voltage(See note 1, 2.): 5VDC, 12VDC, 24VDC.
Compact, Low-cost, SSR Switching 5 to 20 A.
Wide load voltage range: 75 to 264 VAC. Both 100-V and,
200-V loads can be handled with the same model OMRON G3H-203SLN-VD DC12.
Dedicated, compact aluminum PCB and power elements used
G3H-203SLN-VD DC12
Built-in varistor effectively absorbs external surges.
Quick-connect #110 input terminals and #250 output,
connections. (#187 input terminals and #250 output,
connections are available.).
“-US” models certified by UL, CSA, and IEC/EN (TÜV). Standard certification: No.
Action indicator: No.
Applicable load of output: AC100 3A ~ 240V OMRON G3H-203SLN-VD DC12.
Input rated voltage: DC5V.
Insulation mode: three end two-way photoelectric switch.
Zero crossing trigger function.
And the MY type of the same shape of the G3F series of new international standard certification (-VD type).
Achieved UL, CSA, EN (VDE certification) standard certification. (type -VD)
Socket terminal type of same size with MY (2 pole type).
A model with an action indicator to check the status of the input OMRON G3H-203SLN-VD DC12. Fully Sealed Version of G2A that Displays Its.
Power in Adverse Environments.
Exhibits stable performance in an adverse atmosphere of,
harmful gas, moisture, or powdery dust due to its hermetically,
sealed construction.
All the mechanical components of the Relay have been,
annealed to prevent gas generation inside the Relay.
Economical as compared with a hermetically sealed relay in a,
metallic enclosure. Contact form: SPST-NO.
Type: Models with Test Button and Built-in Operation Indicators.
Rated voltage: AC: 24, 100, 110, 120, 200, 220, 230, 240;
DC: 12, 24, 48, 110, 220.
MK-S-series Relays with DC-switching,
Models That Can Switch 220 VDC, 10 A,
(Resistive Load).
Switch a DC load of 220 VDC, 10 A (resistive load).
Models for AC Loads can switch 250 VAC, 15 A (resistive load). G3H-203SLN-VD DC12.
Lineup includes models with SPST-NO and SPST-NO/SPST,
NC contact forms.
Using a SPST-NO/SPST-NC contact form enables detecting,
contact welding. (When the NO contacts become welded, the,
NC contacts will maintain a minimum distance of 0 G3H-203SLN-VD DC12. 5 mm.).
Models available with operation indicators and built-in test buttons.
RoHS compliant.
Standards: UL, IEC (TÜV certification).