Insulation method: Phototriac.
Operation Display: Yes(green).
Output(SSR): AC.
Zero cross Function: NO.
Rated output Load: 2 A(at 100 to 240 VAC).
Rated input voltage (socket): 24 VDC, 24 VAC/VDC.
Applicable model: G3RV-SR700/500-A DC24V, G3RV-SR700/500-A AC/DC24V.
slim I/O solid state relay.
control panel.
in comparison with conventional screw terminals.
traditional screw terminals.).
realizing high reliability.
screwdriver to achieve easier wiring work for stranded wires.
Screw terminal is also stocked to meet the screw type needs.
Mounted relay or solid-state relay has a plug-in terminal.
that is difficult to bend at the time of exchange.
Classification: Standard models.
Rated voltage: Standard products, 12, 24, 100/110, or 200/220 VAC,
12, 24, 48, or 100/110 VDC; Made-to-order items, 110/120 or 220/240 VAC.
New Latching Levers for Circuit Checking.
Added to Our Best-selling.
MY General-purpose Relays.
Now lead-free to protect the environment OMRON G3RV-202SL DC24.
VDE certification (Germany).
Different colors of coil tape for AC and,
DC models to more easily distinguish them
G3RV-202SL DC24
MY(S) models with latching levers added for,
easier circuit checking. Terminal (Wire connection): Push-In Plus Terminal.
Classification: Standard.
Latching lever (Test switch): No.
Rated input voltage: AC/DC, 24V.
Global standard size, low profile slim.
I/O relay with width 6 OMRON G3RV-202SL DC24. 2 mm.
Realized about 25% lower profile than conventional.
products, contributing to further miniaturization of the control panel.
Realized opening and closing ability with one pole 6 A slim shape.
Micro load products for one pole 50 mA using Au-plated.
contacts for small load switching also available.
Since G2RV is a transparent case, confirming the state of,
the contact with the naked eye is possible, and easy to,
confirm abnormality on-site (installed location) OMRON G3RV-202SL DC24.
Screw terminal is also stocked to meet the screw type needs.
Mounted relay uses plug-in terminals that are difficult to,
bend when exchanging. Structure: Relays with Plug-in Terminals.
Classification: Models with diode for coil surge,
absorption (DC coil specification only).
Number of poles: 2.
Power-switching Compact.
General-purpose Relays.
The standard models include models that are,
compliant with the UL, CSA, and SEV safety.
standards and with the Electrical Appliances and,
Material Safety Act.
Equipped with an arc barrier for arc interruption.
Withstand voltages up to 2,000 V.
New built-in diode and built-in CR circuit models have,
joined the series.
The lineup alsso includes models that are compliant,
with the LR and VDE safety standards G3RV-202SL DC24.
Single-pole and double-pole models have AC4,
ratings and DC2 ratings (operating coil ratings:
100/110 VAC, 110/120 VAC, 200/220 VAC, 220/240 VAC,
and 1100/110 VDC) G3RV-202SL DC24.
Three-pole and four-pole models have AC4 ratings,
and DC2 ratings (operating coil ratings: 100/110,
VAC, 200/220 VAC and 100/110 VDC).