MITSUBISHI motor produced PLC connection cable.
Size: A, 1000mm; B, 750mm.
Output use.
Connector cable, MITSUBISHI motor produced PLC connection cable.
No. of poles: 4.
Connection method: Soldering.
Suitable cable dia: 6 mm (5 to 6).
Core conductor size: 0.5 max.
Suitable sheath material: PVC, PE, PUR.
Straight Connectors.
Minimum order: 50.
Round Water-resistive Smartclick.
Connectors That Reduce Installation Work.
A newly developed lock mechanism that is compatible with round M12 connectors OMRON G79-O100C-75-MN.
Simply insert the Connectors, then turn them approximately 1/8 of a turn to lock
G79-O100C-75-MN
A positive click indicates locking.
Features the same degree of protection (IP67) as M12 connectors.
A full line-up of models is planned.
Connectors with Cables are UL approved. Configuration: Covered Power Supplies.
Input voltage: 100 to 240 VAC (free) (80 to 370 VDC *) OMRON G79-O100C-75-MN.
S8JX-G15005@@:Switchable between 100 to 120 VAC and 200 to 240 VAC.
(DC power cannot be input.).
Power ratings: 100 W.
Output voltage: 5 V.
Output current: 20 A.
Built-in fan: No.
Easy-to-use, Widely range from 15 W to 600 W (Output Voltage: 5 V to 48 V).
Easy Mounting: Front-mounted type, DIN rail-mounted type are available.
Screw-mount at the top. (except 300-/600-W models) OMRON G79-O100C-75-MN.
Safety standards: UL 508/60950-1, cUL CSA C22.2 No. 107.1,
cUR CSA C22.2 No. 60950-1.
EN 50178 (= VDE 0160) Over voltage.
category III.
EN 60950-1 (= VDE 0805 Teil 1).
EMC: Conforms to EN 61204-3.
(EMI:EN55011 ClassA).
Input conditions: The input voltage range of 15-W, 35-W,
50-W, 100-W, and 150-W models has,
been increased to 80 to 370 VDC (EC Directives and safety standards do not apply.).Time specification: Instantaneous type.
Current setting range: 8 to 26 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because ooperation time,
is indicated from the start of operation G79-O100C-75-MN.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequeency, basic,
frequency, and load conditions G79-O100C-75-MN. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,