Brand: OMRON
Name: Solid-state timer
Model: H3RN-11
Supply voltage: 24 VAC; 12, 24 VDC.
Time-limit contact: SPDT.
Long-time range model (0.1 min to 10 h).
Ultra-slim Timer for G2R Relay Socket.
Pin configuration compatible with G2R Relay and mounts to the,
P2R/P2RF Socket.
Standard multiple time ranges and multiple operating modes.
Conforms to EN61812-1 and IEC60664-1 4 kV/2 for Low Volt,
age, and EMC Directives.

A Wide Variety of DIN 48 x 48-mm Twin.
Timers, Star-delta Timers, and Power.
OFF-delay Timers.
CE marking.
UL, CSA and CCC certification, conforms to LR.
High immunity against waveform distortion of power supply,
caused by devices like inverters.
Three-language instruction manual provided. ZEN Kit: Set containing CPU Unit (ZEN-10C1DR-D-V2),
Connecting Cable, ZEN Support Software, and manual OMRON H3RN-11 H3RN-11
Even Broader Applications with Increased.
Functionality and Higher Precision.
Increased functionality in a compact body (70 mm wide × 90 mm high).
Easy programming is available using the LCD and operation,
buttons. (See note 1.).
This single Unit easily provides relay, timer, counter, and time,
switch functions OMRON H3RN-11.
Expansion is easy with Expansion I/O Units, allowing up to 44,
I/O points. (See note 2.).
Economy-type and Communications-type CPU Units have been,
added to series.
Improved Weekly Timers (See note 1.).
Increased timing accuracy with a monthly deviation of ±15 s,
max. Multiple-day operation and pulse output operation have,
been added.
Select from two power supply options:
100 to 240 VAC or 12 to 24 VDC OMRON H3RN-11. Type of input: AC voltage input.
Output type: linear; current; NPN open collector (HH, H, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC100 ~ 240V.
96 (W) * 48 (H * 95mm) depth
Some models are not equipped with.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
DeviceNeInput type: DC voltage/current.
Supply voltage: 24 VAC/VDC.
Comparative Output Model: None.
Highly Visible LCD Display with 2-color,
(Red and Green) LEDs.
Multi-range DC voltage/current input.
Front-panel key operation for easy setting.
Average processing function suppresses flicker.
Scaliing, front-panel forced-zero, zero-limit functions H3RN-11.
Easy confirmation of max/min display.
Short 80-mm depth (measured from edge of face plate).
Finger protective cover (standard equipment) guards against electric shock.
Water- and dust-pproof NEMA4X (IP66 equivalent) front panel H3RN-11.
Recognized to U.S. and Canadian requirements under the Component,
Recognition Program of UL.
CE marking.