LK166
Home >> Products >> OMRON >> Control equipments >> Timer / time switch >> Analog timer >> OMRON H3YN-4 Solid-state Timer

OMRON H3YN-4 Solid-state Timer

Brand: OMRON
Name: Solid-state Timer
Model: H3YN-4
Supply voltage: 24, 100 to 120, 200 to 230 VAC;
12, 24, 48, 100 to 110, 125 VDC.
Time-limit contact: 4PDT.
Short-time range model (0.1 s to 10 min).
Miniature Timer with Multiple Time.
Ranges and Multiple Operating Modes.
Minimizes stock.
Pin configuration compatible with MY Power Relay.
Standard multiple operating modes and multiple time ranges.
Conforms to EN 61812-1 and IEC 60664-1 for Low Voltage,
and EMC Directives.

Output: Contact.
Supply voltage: 100 to 240 VAC (50/60 Hz)/100 to 125 VDC;
24 to 48 VAC (50/60 Hz)/12 to 48 VDC.
Input type: No-input available.
Time range: 0.1 s to 600 h.
Operating mode(See note 2): Five multi-modes: A, B,B2, E, J (Power supply start).
Output: Transistor(Photocoupler).
Supply voltage: 24 to 48 VAC (50/60 Hz)/12 to 48 VDC OMRON H3YN-4.
Input type: No-voltage input.
Time range: 0 H3YN-405 s to 300 h.
Operating mode (See note 2): Eight multi-modes: A, B, B2, C, D, E, G, J.
Multiple Operating Modes and Multiple Time.
Ranges. DIN 48 x 48-mm Multifunctional Timer.
A wide AC/DC power supply range greatly reduces the number,
of timer models kept in stock.
A wide range of applications with multiple operating modes,
eight modes for 11-pin models and five modes for 8-pin models OMRON H3YN-4.
Ecological design with reduced current consumption.
Easy sequence checking with instantaneous outputs for a zero set value.
Length of 75 mm or less when panel-mounted with a P3G-08,
Socket (H3CR-A8E, 100 to 240 VAC, 100 to 125 VDC),
PNP input models available.
Standards: UL, CSA, NK, LR, CCC, EN 61812-1, and CE Marking OMRON H3YN-4. Operating modes: Power OFF Delay.
Supply voltage: 24 to 48 VAC/DC.
Control output: Contact output: SPDT.
H3DK-H: S Series (time range: 0.1 to 12 s).
Set two time ranges with each Timer, from 0.1 to 12 seconds for,
the S Series and from 1.0 to 120 seconds for the L Series. Input type: DC voltage input type.
Output type: relay contact; 1c HH; PASS, H, L, LL: each 1a.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC/DC24V.
96 (W) * 48 (H * 95mm) some models are not equipped with depth.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table H3YN-4.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for moniitoring the operation trend H3YN-4.
External event input can be applied to a variety of measurement and identification situations.
Series of DeviceNet type.


...More relevant models >>>>