Universal relay the best-selling MY standard mechanical indicator, can confirm the action state contact.
According to the LED action indicator light color, can identify the AC coil specifications, DC coil specifications.
Online lap tape printing operation coil specifications, the recognition is higher.
All standard specifications indicating mechanism of mechanical action (mechanical indicator).
Type: output module.
Insulation: photo coupler.
Zero crossing function: No.
Action display light: No.
Output rated voltage: AC100 3A ~ 240V.
Input rated voltage: DC4 ~ 24V.
Logic circuit and load interface.
I/O solid state relay.
With the input module (AC, DC), the output module (AC, DC).
Product series, the color of each module to distinguish OMRON MY4-GS DC24.
You can confirm the action of SSR by using the action display light
MY4-GS DC24
Between input and output voltage 4000V. Isolation method: Relay.
Zero cross function: No.
Operation indicator: Yes.
Applicable output load(See note.): 5 A 100 to 240 VAC.
Rated input voltage: 24 VDC.
Hybridization of a Magnetic Relay and an,
SSR Achieves 10-A Switching for 10 Million,
Operations OMRON MY4-GS DC24.
UL/CSA certified (-VD models).
Using a triac to open and close the circuit reduces chattering,
and arching, thereby increasing the electrical durability to 10,
million operations.
Relays contacts for power ON and 10-A switching with high,
capacity are provided in a compact body without the need of,
radiators. Plus, there is almost no effect on heat generation,
or ambient temperature OMRON MY4-GS DC24.
Operation indicators to easily check operation.
Built-in temperature fuse prevents internal burning due to,
triac or relay malfunctions.
Socket-type Relays the same size as the 1-pole and 2-pole,
LY Relays. Classification: Models with built-in diode for coil surge absorption.
Contact configuration: 4 bifurcated.
Rated voltage: Standard products, 24 VDC;
Made-to-order items, 12 or 48 VDC.
New Latching Levers for Circuit Checking.
Added to Our Best-selling.
MY General-purpose Relays.
Now lead-free to protect the environment.
VDE certification (Germany).
Different colors of coil tape for AC and,
DC models to more easily distinguish them.
MY(S) models with latching levers added for,
easier circuit checking. Isolation: Photocoupler.
Zero cross function: Yes.
Indicatoor: Yes MY4-GS DC24.
Applicable output load(See note 2.): 10 A at 24 to 220 VAC (at 40°C).
Rated input voltage: 5 to 24 VDC.
SSR with output (5 to 90 A) at a reasonable price
Zero cross function enables less noise operation.
Built-in varistor efffectively absorbs external surges MY4-GS DC24.
Operation indicator enables monitoring operation.
Protective cover for greater safety.
Certified by UL, CSA and TÜV.