Brand: OMRON
Name: Analog Output Terminal
Model: SRT2-DA02
Classification: Analog Output Terminal.
I/O points: 1 or 2 (selectable with DIP switch).
Compact Analog Output Model is the,
Same Shape as 16-point Remote I/O Terminals.
Two output points or 1 output point is selectable.
Resolution: 1/6,000.
105 x 48 x 50 (W x H x D).

Name: e-CON Connectors.
Specifications: Outputs; 8 outputs ; NPN;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system OMRON SRT2-DA02.
A wide variety of CompoNet Slave Units,
contribute to system size reduction SRT2-DA02
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. I/O classification: Input.
Internal I/O circuit common: NPN (+ common) OMRON SRT2-DA02.
I/O points: 16.
Rated voltage: 24 VDC.
I/O rated voltage: 24 VDC.
Module Type that Allows PCB Mounting.
Compact size at 60 x 16 x 35 (W x H x D).
Lineup now includes the 16-point input model and,
16-point output model. Internal I/O common: PNP.
I/O indicators: LED display (yellow).
Unit power supply current consumption: 120 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
e-CON Connector insertion durability: 50 times OMRON SRT2-DA02.
Weight: 140 g max.
Expansion functions: No.
Short-circuit protection function: Available at input,
section only (Operates at 50 mA/point min.)
Easy wiring using industry standard,
e-CON connectors.
Special wiring tool is not necessary.
Digital I/O terminal with industry,
standard e-CON connectors.
A common terminal is provided for,
each connector.
The I/O terminal and the sensors can,
be connected directly.
Input response time can be switched for,
high-speed processing.
Selectable node address setting methods:
setting with rotary,
switch and with tool software.
When setting the nodes with rotary switch,
setting is easy and node identification,
becomes possible for maintenance. Name: Compact Connectors.
Specifications: Inputs/Outputs; 2 input/2 output; NPN.
Bit slave of smallest class in industry,
Innovation in wiring for any type of machinery.
Available in 2 typees: 2-point Bit Slave Unit,
and 4-point Bit Slave Unit SRT2-DA02.
Compact size for installation in limited space.
Save space and wiring since bit slave can be,
installed near I/O devices.
Industry first bit slave connectable with round,
cabless which can be easily purchased at a lower price SRT2-DA02.
Connectable with flat cables, too for easy wiring.
Cables are selectable depending on applications.