Type: Aggregate model.
DC: Minimum order, 20.
Water- and Environment-resistive FA.
Connectors Save Wiring and Maintenance Effort.
94V-0 fire retardant rating.
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available.
Three types of Connector Assembly: Crimping, soldering, and screw-on.
Connectors with Cables are UL certified.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202.
Cable Specifications: Fire-retardant, Robot cable.
Cable connection direction: L-shaped.
Cable diameter: 6.0 mm dia.
No. of cable cores: 3.
Cable core cross sectional area: 0.5 mm.
Cable length: 10 m.
DC.
Minimum order: 1.
UL-listed: Yes.
Water- and Environment-resistive FA.
Connectors Save Wiring and Maintenance Effort OMRON XS2R-D422-1.
Compact FA connectors meet IP67 requirements and ensure a,
94V-0 fire retardant rating
XS2R-D422-1
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available.
Three types of Connector Assembly: Crimping, soldering, and screw-on.
Connectors with Cables are UL certified OMRON XS2R-D422-1.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202. Control supply voltage: 100 VAC; With voltage fluctuation compensation.
Operating current: 4 to 10 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal.
Precisely singles out the burned element even if one heater el,
ement among several heater elements has been burned out OMRON XS2R-D422-1.
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with both single-phase and three-phase heaters.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage. Control supply voltage: 110 VAC; With voltage fluctuation compensation.
Operating current: 16 to 40 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal.
Precisely singles outt the burned element even if one heater el,
ement among several heater elements has been burned out XS2R-D422-1.
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with booth single-phase and three-phase heaters XS2R-D422-1.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage.