Coil contact between the Part68 FCC standard. (1500V, 10 * 160 s)
Input terminals: M3 terminals.
Isolation method: Phototriaccoupler.
Zero cross function: Yes.
Operation indicator: Yes.
Alarm output: 1 output (Heater Burnout Detection,
SSR Short-circuit Failure Detection, Common).
Applicable load (See note.): 2 to 25 A, 100 to 240 VAC.
A New-concept SSR with Built-in OMRON G5V-1 DC5.
Current Transformer.
Heater Burnout and SSR Short.
circuit Failure Detection
G5V-1 DC5
Built-in Current Transformer (CT) helps reduce wiring steps.
Detects the burnout of any one of a group of heaters.
Detects the burnout of 3-phase heaters.
Detects SSR short-circuit failures.
Error detection level can be easily set with a switch.
Mounts to a DIN track or with screws.
Three types of input terminals available: M3 terminals,
screwless clamp terminals (detachable), or compact slotted,
screw terminals (detachable) OMRON G5V-1 DC5.
Certified for CSA and EN (TÜV).
The G3PF-2@@B-@@@ Series is UL certified. Number of phases: Single-phase.
Insulation method: Phototriac coupler.
Operation indicator: Yes (yellow).
Rated input voltage: 12 to 24 VDC.
Zero cross function: Yes.
Applicable load: 25 A, 100 to 240 VAC OMRON G5V-1 DC5.
Compact, Slim-profile SSRs with Heat,
Sinks. Models with No Zero Cross for,
a Wide Range of Applications.
RoHS compliant.
Models also available with no zero cross,
Surge pass protection improved surge dielectric strength for,
output currents G5V-1 DC5 OMRON. (OMRON testing).
Compact with a slim profile.
Mount to DIN Track or with screws.
Conforms to UL, CSA, and EN standards (TÜV certification) G5V-1 DC5 OMRON. Type: DC-switching.
Contact form: DPDT.
Cased: Plug-in (octal pins)terminals.
Stable Contact Reliability and Long Life.
Easy to mount, wire, and use.
A large selection of models including various contact forms,
DC-switching models, and open models G5V-1 DC5 OMRON.
Mechanical life: 5,000,000 operations; electrical life,
(under rated load): 500,000 operations.
Models also available with built-in diodes and for use as,
auxiliary power relays. Input terminals: Screwless clamp terminals (detachable).
Isolation method: Phototriaccoupler.
Zero cross function: Yes.
Operation indicator: Yes.
Alarm output: 2 outputs (Heater Burnout Detection,
SSR Short-circuit Failure Detection).
Applicable load (See note.): 2 to 25 A, 100 to 240 VAC.
A New-concept SSR with Built-in.
Current Transformer.
Heater Burnout and SSR Short.
circuit Failure Detection.
Built-in Current Transformer (CT) helps reduce wiring steps.
Detects the burnout of any one of a group of heaters.
Detects the burnout of 3--phase heaters G5V-1 DC5.
Detects SSR short-circuit failures.
Error detection level can be easily set with a switch.
Mounts to a DIN track or with screws.
Three types of input terminals available: M3 terminals,
screwless clamp termiinals (detachable), or compact slotted,
screw terminals (detachable) OMRON G5V-1 DC5.
Certified for CSA and EN (TÜV).
The G3PF-2@@B-@@@ Series is UL certified.