Battery replacement.
Initial voltage 3.0V.
Output points: 16 points.
Output voltage and current: DC12~24V; 0.1A/ point; 1.6A/ common.
OFF leakage current: 0.1mA;
Response time: 1ms; 1 point 16 public end; leaky type.
18 point spring clip connection terminal.
With heat protection.
With short circuit protection.
With the surge absorber.
Continue to go beyond, to climb the peak of Q series MITSUBISHI Q6BAT.
Strengthen security function.
Can be set up to 32 characters of the file password
Q6BAT
In addition to the English letters, numbers, but also the use of special characters,
To further enhance the security of the password.
In addition, only pre registered devices are allowed to access CPU,
To intercept unauthorized access to unauthorized users.
Therefore, it is important to prevent the outflow of important program assets and protect intellectual property rights MITSUBISHI Q6BAT.
A variety of modules with excellent performance,
Meet the needs of various control from analog to location.
Q series module products include a variety of types of I/O, analog and positioning function module.
Can fully meet the switch, sensor, such as the input and output, temperature, weight, flow and motor, drive control,
As well as the requirements of high-precision control of the positioning of the industry, the control needs of various fields MITSUBISHI Q6BAT.
Can also be used in combination with the CPU module to achieve appropriate control Q6BAT MITSUBISHI.
Easy connection programming tool via ethernet.
Programming tools (Works2 GX, Developer GX) and CPU direct connection (1 to 1),
No need to carry out the IP address settings Q6BAT MITSUBISHI. And there is no need to select the cable, the straight line and the cross line can be used.
Therefore, this connection method and the use of USB, can easily communicate with the CPU,
Even the operators are not familiar with the network settings can easily establish a connection Q6BAT MITSUBISHI. Master / local station sharing.
IE CC-Link field network.
Make the mixed data environment intelligent, to achieve a new manufacturing system IE CC-Link field network module.
Using Ethernet cables and connectors available on the market to reduce costs.
High speed communication capable of communicating with 1Gbps.
Improve the communication response, significantly shorten the cycle time.
Improve the performance of cycle data update. Reduces the transmission delay time and the application of the synchronization waiting time.
Data can be rread or written to other station programmable controller Q6BAT.
Status of IE CC-Link field network can be confirmed by Works2 GX.
Can be in the Works2 GX up and down the abnormal position, the cause of the exception, the event record,
So it can reduce the time of abnormal to resume normal operation MITSUBISHI Q6BAT.
QJ71GF11-T2 can be used as the main station / local station of IE CC-Link field network.