Control mode: loop program execution.
Input / output control mode: refresh mode.
Programming language: ladder diagram, function block.
Processing speed (CIS): 0.10 s.
Program capacity: 14k step.
Security PLC (secure programmable system) refers to the self or external components or the implementation of the failure of the agency,
Can still respond to and promptly cut off the output of the programmable system.
Different from ordinary PLC, security PLC not only can provide the function of ordinary PLC,
Meet the requirements of the ISO 13849-1 EN and IEC 61508 control system safety related component standards.
PSS 4000 in addition to the security process can also be processed outside the standard control procedures.
If any inconsistency occurs during the process, the system is immediately shut down.
Category: Category 4 (EN/ISO13849-1), class 4 (EN954-1).
Security level: SIL, CL3 SIL3.
Performance level: PLe.
EFI connecting port number: 0.
EFI connection method: -.
Setting interface: RS-232.
Use special setting monitoring tools to configure the configuration directly.
Constitute a rich set of components can be easily and quickly set the hardware structure MITSUBISHI QS001CPU.
Creating logic for security devices, by using the automatically generated labels of the FB can easily create logic
QS001CPU
Logical import and export.
You can store the connection settings of the input and output modules and the application logic created by the function block as a setting file,
Or read from a saved set file. Functional security based on EN954: category 4 MITSUBISHI QS001CPU.
Functional security based on SIL3: IEC61508.
Use special setting monitoring tools to configure the configuration directly.
Constitute a rich set of components can be easily and quickly set the hardware structure.
Creating logic for security devices, by using the automatically generated labels of the FB can easily create logic.
Logical import and export.
You can store the connection settings of the input and output modules and the application logic created by the function block as a setting file,
Or read from a saved set file MITSUBISHI QS001CPU. Meet safety standards: EN954-1 class 4, 13849-1 PL e ISO QS001CPU MITSUBISHI.
Safe input points: 1 points (2 input).
Start input points: 1.
Input type: N type (positive public end / negative public end input)
Safe output points: 1 points (3 output) QS001CPU MITSUBISHI.
Spring clip terminal.
Additional security system.
Simply connect to the existing CC-LINK, you can add an independent security features.
Saving wiring by CC-link connection.
The wiring is not needed in particular to the condition monitoring of the safety relay module, and realizes the wiring of the cabinet and the other provinces QS001CPU MITSUBISHI QS001CPU.
Visualization of installation status.