Rated voltage: 200 V.
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated rotational speed: 50 Hz, 2650 r/min; 60 Hz, 3000 r/min.
Maximum flow rate: 50 Hz, 1.1 m3/min; 60 Hz, 1.3 m3/min.
Maximum static pressure: 50 Hz, 67 Pa; 60 Hz, 63 Pa.
Noise: 50 Hz, 45 dB; 60 Hz, 48 dB.
Weight: Approx. 1150 g.
Comprehensive Lineup of Single,
Double, and Triple Axial Fans with,
Easy One-step Mounting.
Mounts in a square cutout and conceals the hole-cut to,
simplify installation work.
Cover can be set to open either upward or downward for,
convenience in confined spaces.
Enhanced accessories (finger guard, filter, plug cord,
mounting screws).
Optional Replacement Filter and Vent Attachment.
The lineup includes Single, Double, and Triple Box Fans,
with eight models with plastic blades and eight models with,
metal blades.

Control power supply voltage: 100/110 VDC.
Input: DC or AC (selectable), Input voltage range, 0.2 to 12 V.
Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL) OMRON R87B-TA4A15HPF.
Detect three-phase AC current for under and/or overcur,
rent using current converter R87B-TA4A15HPF
Available in 7 supply voltage configurations.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T).
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verse current detection.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F) OMRON R87B-TA4A15HPF.
LED operation indicator.
UL/CSA approval (SDV-F@). Rated voltage: 100 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.230 A; 60 Hz, 0.220 A.
Rated input: 50 Hz, 15 W ; 60 Hz, 14 W .
Rated rotational speed: 50 Hz, 2,750 r/min; 60 Hz, 3200 r/min.
Maximum flow rate: 50 Hz, 2 OMRON R87B-TA4A15HPF. 7 m3/min; 60 Hz, 3.1 m3/min.
Maximum static pressure: 50 Hz, 93.1 Pa; 60 Hz, 99.0 Pa.
Noise: 50 Hz, 42 dB; 60 Hz, 46 dB.
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment R87B-TA4A15HPF OMRON.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 type) and metal-bladed models,
(28 type) included in series R87B-TA4A15HPF OMRON.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certified safety standards depend on the,
product. Check the information given for available models of Axial fans and,
the information in Characteristics R87B-TA4A15HPF OMRON. Time specification: Inverse type.
Current setting range: 8 to 26 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation R87B-TA4A15HPF.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions OMRON R87B-TA4A15HPF. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.


...More relevant models >>>>
Related model