Rated voltage: 200 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.096 A; 60 Hz, 0.078 A .
Rated input: 50 Hz, 14 W ; 60 Hz, 12 W .
Rated rotational speed: 50 Hz, 2400 r/min; 60 Hz, 2800 r/min.
Maximum flow rate: 50 Hz, 1.9 m3/min; 60 Hz, 2.2 m3/min.
Maximum static pressure: 50 Hz, 44.1 Pa; 60 Hz, 42.2 Pa.
Noise: 50 Hz, 39 dB; 60 Hz, 43 dB.
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
environment.
Shaft supported by ball bearings for highly-reliable operation.
(28 type) included in series.
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
product. Check the information given for available models of Axial fans and,
the information in Characteristics.
Ideal for 3-phase Voltage Asymmetry.
Monitoring for Industrial Facilities and Equipment.
Greater resistance to inverter noise.
Monitor voltage asymmetry, phase sequence, and phase,
loss for three-phase 3-wire or 4-wire power supplies with just one Unit.
Switch setting for 3-phase 3-wire or 3-phase 4-wire power supply OMRON R87F-A4A13HP.
One SPDT output relay, 5 A at 250 VAC (resistive load)
R87F-A4A13HP
World-wide power specifications supported by one Unit (switchable).
Relay status can be monitored using LED indicator. Category: relay output.
Points: 8 points (1a * 8).
Common line processing on the connector side: corresponding (+ public).
Rated voltage: DC24V.
To achieve the control cabinet of miniaturization / save time,
Relay terminal for 8 point output OMRON R87F-A4A13HP.
Small size of 136 * high 80 * 55mm. (vertical installation)
The total wiring of the connector cable is realized.
The common end can be easily connected with the independent contact and the short circuit piece.
The G70D-SOC08 and G70R-SOC08 are connected by a short circuit chip.
When the relay does not need the tool, the relay is convenient to replace the work OMRON R87F-A4A13HP.
With terminal cover to prevent electric shock.
Diode for internal coil surge absorption.
DIN guide rail installation, screw mounting common. Time specification: Inverse type.
Current setting range: 20 to 65 A R87F-A4A13HP OMRON.
Operating voltage: 400/440 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase) R87F-A4A13HP OMRON.
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation R87F-A4A13HP OMRON R87F-A4A13HP.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions OMRON R87F-A4A13HP. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.