LK166
Home >> Products >> MITSUBISHI >> R series PLC >> Motion / position / high speed counter module >> RD77MS4 MITSUBISHI RD77MS4

RD77MS4 MITSUBISHI RD77MS4

Brand: MITSUBISHI
Name: Simple motion module
Model: RD77MS4
Axis of control: 4.
Operation cycle: 0.444ms, 0.888ms, 1.777ms, 3.555ms.
Control unit: mm, inch, degree, pulse.
Location data: 600 data / axis.
Boot time (operation cycle 0.444ms, 1 axes): 0.7ms.
Servo amplifier connection mode: SSCNET III /H.
Inter station distance (max): 100m.
External wiring connection: 40 pin connector two.
Straight line interpolation: 2 axis, 3 axis, 4 axis.
Arc interpolation: 2 axes.
Positioning control (sealant / adhesive coating equipment etc.).
Synchronous control / electronic cam control (pick and place machine, packing machine, etc.).
Speed / torque control (stamping machine, die casting machine, etc.).
Speed / position control switching (production of semiconductor chips, etc.).
IQ-R MELSEC series of simple movement module, positioning module, high-speed counter module for intelligent function module,
High speed and high precision motion control, position control and position detection can be carried out by simple programming.
The simple motion module has the same operation convenience as the positioning module,
Like motion controller for synchronous control, cam control and other advanced control.
Can be connected to the servo system dedicated to support high-speed synchronous network /H III SSCNET servo amplifier.
Motion control by simple programming.
Can be realized through the software gear, shaft, transmission, cam action.
The most suitable for milling spiral line interpolation.
Normal start, high speed start, multi axis simultaneous start.
High precision ON/OFF pulse time measurement.

Analog input channel number: 8CH.
accuracy
Ambient temperature of 25 plus or minus 5 degrees C: plus or minus 0.1%.
Ambient temperature 0 ~ 55 degrees C: plus or minus 0.3%.
Temperature coefficient.
Common
Conversion speed: 80 s/CH.
Channel to channel insulation.
Absolute maximum input: 30mA.
External wiring connection mode: 18 point screw terminal MITSUBISHI RD77MS4.
Voltage input
Analog input voltage: - RD77MS4
Digital output value: -.
Current input
Analog input current: DC0 ~ 20mA.
Digital output value: 0 ~ 32000.
16 bit high resolution (1/32000).
No program can perform scaling and conversion operations.
The most suitable for the requirements of speed and accuracy of the detection equipment.
Easy to filter high frequency interference MITSUBISHI RD77MS4.
Execute event driven programs via alarm output.
Through the engineering software, the output of arbitrary analog waveform data.
Reduce downtime and reduce maintenance costs through anomaly detection
Works3 GX can be used to easily set the critical value of the input and output signals.
Can quickly detect the abnormal signal, so it can shorten the downtime, reduce maintenance costs MITSUBISHI RD77MS4.
Channel insulation can ensure the accurate signal transceiver.
Model with " -G " module in the channel between the insulation,
Isolation amplifiers are not required to prevent inter channel current and interference current. 1Gbps, fiber optic cable, management station / general station.
IE CC-Link controller network is a kind of controller network based on Gigabit Ethernet,
The most suitable for large scale controller decentralized control.
With high speed (1Gbps), large capacity (128K word), using the characteristics of the dual loop fiber,
Controller network system capable of constructing high reliability.
The fault prone high reliability fiber double loop network is not easy to be transmitted by using the double loop transmission of the strong anti interference fiber cable,
In the event of cable disconnection or power failure, etc., but also through the ring back function to continue communication.
Quick find line fault,, module exception
The overall situation of the IE CC-Link controller network can be visualized by engineering software, and the circuit fault and module exception can be found quickly RD77MS4.
Therefore, in case of failure, can quickly identify abnnormal parts, in order to shorten the system down time RD77MS4.
In addition, the network can also monitor the status of other stations programmable controller.


...More relevant models >>>>