LK166
Home >> Products >> MITSUBISHI >> R series PLC >> Input / output module >> RX61C6HS MITSUBISHI Extension module

RX61C6HS MITSUBISHI Extension module

Brand: MITSUBISHI
Name: Extension module
Model: RX61C6HS

Operation control mode: stored procedure repeated operation.
Built in IE CC-Link.
Input / output points: 4096 points.
Program capacity: 160K step.
Easy to collect and display the value of soft component.
With simple parameter setting, the value of the soft component can be collected as the record data,
Save to the SD memory card, or through the USB/ Ethernet for real-time monitoring RX61C6HS MITSUBISHI RX61C6HS
Using the data collected by the recording function to support the Unicode text format,
Can be easily recognized by LogViewer GX and spreadsheet software.
In addition, LogViewer GX can also be used to monitor the function of real time,
Easily confirm the time of small changes in the object''s soft components.
These features can be traced back to improve and set up a fault when the commissioning of a great help RX61C6HS MITSUBISHI. "Enter points: 64 points.
Rated input voltage and frequency: DC24V.
Rated input current: TYP 4.0mA.
Response time: 0.1 ~ 70ms.
Common way: 32 point / public end.
Interrupt function: have.
External wiring connection: 40 pin connector two.
Easily connect input and output terminals with high density RX61C6HS MITSUBISHI.
An input / output module with 16 points, 32 points, 64 points is provided.
According to the user system to select the most suitable models, help to save space and cost.
The terminal row is compatible with the Q series, and can be used directly by the terminal of the existing system.
Therefore, the wiring cost can be reduced when the system is updated.
The module design of the pursuit of convenience".
Paste the white label on the input module and paste the red label on the output module,
The rated specifications are clearly marked on the front of the module, which can prevent the use of errors.
The input and output number stamped on the top of the front display input and output module LEDD, can easily confirm the status of the ON/OFF RX61C6HS.
The terminal arrangement of each signal is recorded on the wiring terminal of the 16 point module, and the false wiring can be prevented.
The 64 point module can be 32 points as the unit, throough the switch to switch to display the input and output number RX61C6HS.
In addition, serial number tag in the front of the module, can be easily recognized. "


...More relevant models >>>>