Cable Specifications: Standard cable (non-polar).
Cable connection direction: Straight.
Cable diameter: 6.0 mm dia.
No. of cable cores: 2.
Cable core cross sectional area: 0.5 mm.
Cable length: 2 m.
AC.
Minimum order: 5.
UL-listed: --.
Water- and Environment-resistive FA.
Connectors Save Wiring and Maintenance Effort.
94V-0 fire retardant rating.
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available.
Three types of Connector Assembly: Crimping, soldering, and screw-on.
Connectors with Cables are UL certified.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202.
Type: S8JC-ZS series models list.
Meet the criteria: CE (EN50178).
Configuration: power supply with cover; DIN guide rail mounting.
Input voltage: 350W.
Output voltage: 5VDC.
Output current: 50.0A.
Economic type power supply S8JC-Z additional models,
The new power S8JC-ZS has a CE certification mark to market OMRON XS2F-A421-310.
Product features: reduce material costs;
Export machinery to be used to meet specific safety standards;
Through the DIN guide rail installation, significant savings in time
XS2F-A421-310 Time specification: Instantaneous type.
Current setting range: 20 to 65 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase) OMRON XS2F-A421-310.
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation OMRON XS2F-A421-310.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions XS2F-A421-310 OMRON. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Input / output: 20.
Pole number: 20 XS2F-A421-310 OMRON.
I/O: input and output.
Common mode terminal: NO.
Connector mounting type: XG4A-2031.
Cable connector type: XG4M-2030-T.
The use of non threaded terminals can greatly reduce the amount of plant wiring and the required hours.
The caliper terminal so that you can no longer without fastening screws XS2F-A421-310 OMRON.
Only insert the rod - shaped terminal to complete a touch type wiring. Setting range: 1 to 10 V AC/DC, 3 to 30 V AC/DC, 15 to 150 V AC/DC.
Power supply voltage: 24 VAC/DC.
Ideal for Voltage Monitoring for.
Industrial Facilities and Equipment.
Monitor for overvoltages and undervoltages simultaneously.
Separate settings and outputs supported for overvoltages and undervooltages XS2F-A421-310.
Manual resetting and automatically resetting supported by one Relay.
Pre-alarm Monitoring Mode.
Two SPDT output relays, 5 A at 250 VAC (resistive load).
Process control signal (0 to 10 V) and current splitter input ssupported OMRON XS2F-A421-310.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply.