Power rating: 50 W.
Input voltage: 100 to 240 VAC (allowable range: 85 to 264 VAC or 120 to 370 VDC*1).
Output voltage: 48 V VDC.
Output current: 1.1 A.
Built-in fan: None.
Model with terminal block facing forward.
High Reliability at a Reasonable Cost.
Contribute to Stable Equipment Operation.
operation even with an unstable input voltage.
to achieve stable quality and long life. A reliable 3-year warranty.
voltages and capacities used in FA applications.
Approved for UL (all models) and CCC (15 to 150-W models).
Easy mounting to DIN Rails with Mounting Brackets (sold separately).
Refer to Period and Terms of W.
Ideal for Monitoring 3-phase Power.
Supplies for Industrial Facilities and Equipment.
Greater resistance to inverter noise.
Monitor overvoltages, undervoltages, phase sequence,
and phase loss for three-phase 3-wire or 4-wire power,
supplies with just one Unit.
Switch setting for 3-phase 3-wire or 3-phase 4-wire power supply OMRON S8FS-C05048J.
Two SPDT output relays, 5 A at 250 VAC (resistive load)
S8FS-C05048J
Output overvoltages and undervoltages using separate relays.
World-wide power specifications supported by one Unit (switchable).
Output status can be monitored using LED indicator. Appearance: insert type.
Control supply voltage: AC200/220/240V.
Action elements: overload detection.
Action characteristic: anti time limit action type OMRON S8FS-C05048J.
Especially suitable for single phase motor over current protection.
Can be used for motor overload protection, common single-phase circuit of the AC current detection.
A variety of models, such as anti time limit characteristics, lock time, instantaneous action, etc., are provided,
The product is rich in variety, and can be effectively protected, detected and controlled according to the actual situation OMRON S8FS-C05048J.
When the current is large, the input resistance of the CT or the relay part is not needed, and the use is simple.
Because it is a plug-in, installation, disassembly, wiring and other operations are very simple S8FS-C05048J OMRON. Power supply voltage: 100 to 240 VAC.
Heater control method: ON/OFF control SSR control.
Input specifications: Two current inputs,
(for either single phase or threephase) S8FS-C05048J OMRON.
Output specifications: One relay output.
Communications output: RS-485.
Current input range: 0.200 to 2.200 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload S8FS-C05048J OMRON.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phaase control, and cyclic control S8FS-C05048J.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurreent relay or for motor or lamp loads OMRON S8FS-C05048J.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@).