Power rating: 75 W.
Input voltage: 100 to 240 VAC (allowable range: 85 to 264 VAC or 120 to 370 VDC*1).
Output voltage: 48 V VDC.
Output current: 1.6 A.
Built-in fan: None.
Model with terminal block facing upward.
High Reliability at a Reasonable Cost.
Contribute to Stable Equipment Operation.
operation even with an unstable input voltage.
to achieve stable quality and long life. A reliable 3-year warranty.
voltages and capacities used in FA applications.
Approved for UL (all models) and CCC (15 to 150-W models).
Easy mounting to DIN Rails with Mounting Brackets (sold separately).
Refer to Period and Terms of W.
Model: PY (back-mounting), page 15, PCB terminals.
Number of pins: 14 pins.
A Wide Variety of Square and,
Round Sockets in Front-mounting,
and Back-mounting Models,
Models available with finger protection.
Hold-down Clips and Socket Bridges for PYF Sockets,
are also available.
New screwless models available OMRON S8FS-C07548. Time specification: Inverse type.
Current setting range: 20 to 65 A
S8FS-C07548
Operating voltage: 100/110/120 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase OMRON S8FS-C07548.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions OMRON S8FS-C07548. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Rated voltage: 200 V.
Permitted voltage fluctuation range: 85% to 110% rated voltage S8FS-C07548 OMRON.
Frequency: 50/60 Hz.
Rated rotational speed: 50 Hz, 2100 r/min; 60 Hz, 2200 r/min.
Maximum flow rate: 50 Hz, 0 S8FS-C07548 OMRON. 9 m3/min; 60 Hz, 1.0 m3/min.
Maximum static pressure: 50 Hz, 43 Pa; 60 Hz, 42 Pa.
Noise: 50 Hz, 42 dB; 60 Hz, 43 dB.
Weight: Approx. 1120 g.
Comprehensive Lineup of Single,
Double, and Triple Axial Fans with,
Easy One-step Mounting.
Mounts in a square cutout and conceals the hole-cut to,
simplify installlation work S8FS-C07548 OMRON S8FS-C07548.
Cover can be set to open either upward or downward for,
convenience in confined spaces.
Enhanced accessories (finger guard, filter, plug cord,
mounting screws).
Optional Replacement Filter and VVent Attachment OMRON S8FS-C07548.
The lineup includes Single, Double, and Triple Box Fans,
with eight models with plastic blades and eight models with,
metal blades.