Power rating: 350 W.
180 to 264 VAC, or 254 to 373 VDC(Select with the switch.)*2).
Output voltage: 5 V VDC.
Output current: 60 A.
Built-in fan: Yes.
Model with terminal block facing upward.
High Reliability at a Reasonable Cost.
Contribute to Stable Equipment Operation.
operation even with an unstable input voltage.
to achieve stable quality and long life. A reliable 3-year warranty.
voltages and capacities used in FA applications.
Approved for UL (all models) and CCC (15 to 150-W models).
Easy mounting to DIN Rails with Mounting Brackets (sold separately).
Refer to Period and Terms of W.
Rated voltage: 100 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.180 A; 60 Hz, 0.160 A .
Rated input: 50 Hz, 12 W; 60 Hz, 10 W.
Rated rotational speed: 50 Hz, 2800 r/min; 60 Hz, 3300 r/min.
Maximum flow rate: 50 Hz, 0.80 m3/min; 60 Hz, 0 S8FS-C35005 OMRON. 90 m3/min.
Maximum static pressure: 50 Hz, 42 Pa; 60 Hz, 58 Pa.
Noise: 50 Hz, 37 dB; 60 Hz, 40 dB
S8FS-C35005
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 type) and metal-bladed models,
(28 type) included in series S8FS-C35005 OMRON.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certified safety standards depend on the,
product. Check the information given for available models of Axial fans and,
the information in Characteristics. Type: open type.
Structure: bottom mounting type.
Capacity: 30W S8FS-C35005 OMRON.
Output voltage: 24V.
Output current: 2.2A.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
(except for the 300/600/1500W output terminalls)
Support finger touch protection to prevent electric shock S8FS-C35005.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable whhen the fan is replaced by the customer S8FS-C35005. )
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)