LK166
Home >> Products >> OMRON >> Power/other peripheral devices >> Power Supply >> Switching power >> S8JC-ZS03512CD-AC2 | OMRON S8JC-ZS03512CD-AC2 Switching Mode Power Supply

S8JC-ZS03512CD-AC2 | OMRON S8JC-ZS03512CD-AC2 Switching Mode Power Supply

Brand: OMRON
Name: Switching Mode Power Supply
Model: S8JC-ZS03512CD-AC2
Type: S8JC-ZS series models list.
Meet the criteria: CE (EN50178).
Configuration: power supply with cover; DIN guide rail mounting.
Input voltage: 35W.
Output voltage: 12VDC.
Output current: 3.0A.
Economic type power supply S8JC-Z additional models,
The new power S8JC-ZS has a CE certification mark to market.
Product features: reduce material costs;
Export machinery to be used to meet specific safety standards;
Through the DIN guide rail installation, significant savings in time.

Sensor type and connection: 3 line DC (NPN) /2 line 3-4.
Actuator connection: actuator connection 1-4.
Port number: 4.
Cable length: 5m.
This series contains the optimal control case of the new thin,
Light connector terminal box, has better,
Environmental resistance and centralized management of I/O sensor connector,
Therefore, less artificial OMRON S8JC-ZS03512CD-AC2.
Wear resistant thin, protection grade can reach IP67 S8JC-ZS03512CD-AC2
Suitable for photoelectric sensor,
Proximity sensor and sensor with I/O connector (M12) limit switch.
In addition, due to the increase of the rated current, the ground terminal is increased,
So it can support and connect the valve solenoid.
Contains power and action indicator light.
No matter how many ports are used, the installation method is used,
To ensure that the system can be easily expanded OMRON S8JC-ZS03512CD-AC2. Sensor type and connection: 2 line DC1-4/ non polarity 3-4.
Actuator connection: -.
Port number: 6.
Cable length: 5m.
This series contains the optimal control case of the new thin,
Light connector terminal box, has better,
Environmental resistance and centralized management of I/O sensor connector,
Therefore, less artificial OMRON S8JC-ZS03512CD-AC2.
Wear resistant thin, protection grade can reach IP67.
Suitable for photoelectric sensor,
Proximity sensor and sensor with I/O connector (M12) limit switch.
In addition, due to the increase of the rated current, the ground terminal is increased,
So it can support and connect the valve solenoid S8JC-ZS03512CD-AC2 OMRON.
Contains power and action indicator light.
No matter how many ports are used, the installation method is used,
To ensure that the system can be easily expanded S8JC-ZS03512CD-AC2 OMRON. Appearance: there are F4 shell, R2 shell.
Circuit structure and open circuit mode: single contact 1C, voltage, no voltage, DC circuit breaker.
Rated current: AC5A.
Rated frequency: 50/60Hz (switching) S8JC-ZS03512CD-AC2 OMRON.
Current adjustment range: time limit elements: 3-3.5-4-4.5-5-6A, 6 shunt;
Instantaneous elements: 20-30-40-50-60A-, 6 shunt.
Action time: time limit element time to adjust the degree 0.25-0.5-1-2-3-4-5-6-7-8-9-10,
12 nominal action time to adjust the scale of 10300% over current, 10s plus or minus 5%,
700% over current, 1.52s plus or minus 7%; instantaneous elements, nominal action time 200% over current 40ms.
Control power supply: do not.
Rated consumption VA:6VA.
Contact capacity: closed circuit, 110V 5A L/R=0ms1000 DC220V times, 10A L/R=0ms1000 DC times;
30W (DC 110V 1A closed, L/R=25ms1000), 80VA (AC 220V 1A) cos with =0.1 1000.
Contact: AC110V, 7.5A, COS with =0.4; (AC250V 825VA)
DC24V, 5A, L/R=7ms (maximum 50W time DC125V).
Automatic experiment: No.
Display: start display (LED), after the time display (LED).
Output display, trip (R phase and T phase) manual reset type, instant manual reset type.
Excitation surge current suppression (fuzzy inference): -.
Quality: about 1.3KG (R2 shell), about 1.8kg (F1 shell), about 3.3kg (D2 shell).
External: Mount Searl N1.5.
Static type over current relay K2CA-D type, attention to the protection of the coordination of static type OCR.
The protection coordination bettween OCR and MCCB is simple S8JC-ZS03512CD-AC2.
1 sets of three-phase protection, can save space and manpower.
Compared with the plate movement start display, through time display, make maintenance and inspection becomes simple.
The display oof the accident occurrence phase is used to facilitate the inspection after the accident OMRON S8JC-ZS03512CD-AC2.
Reduce the consumption of VA, reduce the burden of converter.


...More relevant models >>>>
Related download