LK166
Home >> Products >> OMRON >> Power/other peripheral devices >> Power Supply >> Switching power >> S8VK-C24024 OMRON Switch Mode Power Supply

S8VK-C24024 OMRON Switch Mode Power Supply

Brand: OMRON
Name: Switch Mode Power Supply
Model: S8VK-C24024
Power ratings: 240 W.
Input voltage: Single phase, 100 to 240 VAC, 90 to 350 VDC.
Output Voltage: 24 V.
Output current *1: 10 A.
Cost-effective Single Phase Power Supply.
Universal input and Safety standards.
for worldwide applications.
Space-saving Compact Design.
Universal input for worldwide applications:
100 to 240 VAC (85 to 264 VAC).
DC input can be available: 90 to 350 VDC.
Operation temperature range: –25 to 60 °C.
Compact Dimension for small space.
Flexible installation by special mounting brackets.
Safety standards:
UL508/60950-1, CSA C22.2 No.107.1/60950-1.
EN50178, EN60950-1.
EMS: Conform to EN61204-3.
EMI: EN55011 Class A.
Three years Warranty.

SYSMAC PLC Units: CQM1-CPU21, CQM1-CPU41, CQM1-CPU42, CQM1-CPU43,
CQM1-CPU44, (Units with RS-232C port), C200HS-CPU31/33/21/23,
CV500/1000/2000-CPU01, CVM1-CPU01/11, CV500-LK201, (Communications port 2),
C200HE-CPU42, C200HG-CPU43/63, C200HX-CPU44/64, C200HW-COM02,
C200HW-COM04, C200HW-COM05, C200HW-COM06, CPM1-CIF01 S8VK-C24024 OMRON.
Cable length L: 2 m.
Host: Personal computer: IBM PC/AT or compatible S8VK-C24024
Ideal Cables for between Programmable Controllers and Host Computers. Category: incidental cover type.
Structure: bottom surface mounting type (300/600/1500W type forced cooling with built-in fan).
Capacity: 30W.
Output voltage: 24V.
Output current: 1.3A.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device S8VK-C24024 OMRON.
Built in support for determining the abnormal causes of the new under voltage detection function.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free S8VK-C24024 OMRON.
Humanized design of anti - shedding screw for terminal stage.
(except for the 300/600/1500W output terminals)
Support finger touch protection to prevent electric shock.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable when the fan is replaced by the customer.)
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)
"
Rated voltage: 230 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.046 A; 60 Hz, 0.039 A .
Rated input: 50 Hz, 7 W ; 60 Hz, 6 W .
Rated rotational speed: 50 Hz, 2600 r/min; 60 Hz, 3000 r/min.
Maximum flow rate: 50 Hz, 0.6 m3/min; 60 Hz, 0.7 m3/min.
Maximum static pressure: 50 Hz, 39.2 Pa; 60 Hz, 53.9 Pa.
Noise: 50 Hz, 32 dB; 60 Hz, 36 dB.
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 type) and meetal-bladed models,
(28 type) included in series S8VK-C24024.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certiffied safety standards depend on the,
product S8VK-C24024. Check the information given for available models of Axial fans and,
the information in Characteristics.


...More relevant models >>>>