Category: incidental cover type.
Structure: bottom surface mounting type (300/600/1500W type forced cooling with built-in fan).
Capacity: 30W.
Output voltage: 5V.
Output current: 6A.
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function.
Power failure detection function with built-in hint output voltage abnormity.
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
Support finger touch protection to prevent electric shock.
DIN guide rail simple installation.
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable when the fan is replaced by the customer.)
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)
Time specification: Inverse type.
Current setting range: 8 to 26 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage OMRON S8VM-03005C.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase
S8VM-03005C
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions OMRON S8VM-03005C. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Rated voltage: 230 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.210 A; 60 Hz, 0 OMRON S8VM-03005C. 190 A .
Rated input: 50 Hz, 43 W; 60 Hz, 40 W.
Rated rotational speed: 50 Hz, 2800 r/min; 60 Hz, 3250 r/min.
Maximum flow rate: 50 Hz, 5.0 m3/min; 60 Hz, 5.8 m3/min.
Maximum static pressure: 50 Hz, 118 Pa; 60 Hz, 88 Pa S8VM-03005C OMRON.
Noise: 50 Hz, 52 dB; 60 Hz, 56 dB.
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment S8VM-03005C OMRON.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 type) and metal-bladed models,
(28 type) included in series.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA S8VM-03005C OMRON.
Note: The compliant standards and certified safety standards depend on the,
product. Check the information given for available models of Axial fans and,
the information in Characteristics S8VM-03005C. New Screwless Terminal Sockets Added.
for MY and G2R Relays.
Simplified wiring without tightening screws.
Two wires can be independently wired for each terminal.
Coil terrminals and contact terminals are completely separated,
in an organized wiring layout OMRON S8VM-03005C.
Release Levers and Nameplates are available (sold separately).